101603-8230 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016038230 8943949150


101603-8230 INJECTION-PUMP ASSEMBLY
Rating:
75
Buy INJECTION-PUMP ASSEMBLY 101603-8230 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-8230 1016038230
ISUZU 8943949150 8943949150

Cross reference number

ZEXEL 101603-8230 1016038230
ISUZU 8943949150 8943949150


Zexel num
Bosch num
Firm num
Name
101603-8230 
101603-8231 
 
8943949150  ISUZU
INJECTION-PUMP ASSEMBLY
6HE1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.2 4.15 4.25
Rack position
After adjusting injection quantity.
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.1
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   69 67.4 70.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.8+-0.5
Pump speed r/min   265 265 265
Average injection quantity mm3/st.   18.2 16.9 19.5
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.1)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   69 68 70
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   103 103 135
Fixing the lever   *
Timer adjustment
Pump speed r/min   (1220)
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1300
Advance angle deg.   1.3 0.8 1.8
Timer adjustment_03
Pump speed r/min   1500
Advance angle deg.   5.5 5 6
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-8230
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=G16
----------

Speed control lever angle

Test data 101603-8230
F:Full speed I:Idle (1)Use the pin at R = aa (2)Stopper bolt set position 'H'
----------
aa=36mm
----------
a=12.5deg+-5deg b=(45deg)+-3deg

Stop lever angle

Test data 101603-8230
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=45mm
----------
a=12.5deg+-5deg b=40deg+-5deg

0000001501 I/P WITH LOAD PLUNGER ADJ

Plunger assembly number: PL (stamping: ST) 1. Adjustment procedures (1)Insert the pre-stroke adjusting shims L1 for each cylinder. (2)Adjust injection quantity.(max. var. bet. cyl. idling a1, full a2) (3)At basic point A, adjust so that the pre-stroke is L2. (4)Reconfirm the injection quantity.
----------
PL=131153-4520 ST=A724 L1=1mm L2=4.2+-0.05mm a1=+-14% a2=+-2.5%
----------

Timing setting

Test data 101603-8230
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)- (5)Pump vertical direction (6)Direction of rotation (7)Pointer (8)Pointer stamping (9)Timing device stamping (10)Timing device (11)Stamp both at the same time as shown above. (12)Outside circumference of timing device (13)Secondary timing stamping position for the No. 1 cylinder's beginning of injection
----------
aa=11deg bb=1deg
----------
a=(150deg) b=1deg




Have questions with 101603-8230?





Group cross 101603-8230 ZEXEL

Isuzu 

9 400 615 250 
1156029050 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156029000 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156029001 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
8943949140 
INJECTION-PUMP ASSEMBLY
6HE1
9 400 615 251 
8943949141 
INJECTION-PUMP ASSEMBLY
6HE1
101603-8230  

101603-8231 
 
8943949150 
INJECTION-PUMP ASSEMBLY
6HE1
9 400 615 252 
 
INJECTION-PUMP ASSEMBLY
6HE1

Isuzu 

9 400 615 252 
8943949151 
INJECTION-PUMP ASSEMBLY
6HE1
F 019 Z10 362 
8943937530 
INJECTION-PUMP ASSEMBLY
6HE1-TC1
F 019 Z10 363 
8943937531 
INJECTION-PUMP ASSEMBLY
6HE1-TC1
9 400 615 253 
8943937532 
INJECTION-PUMP ASSEMBLY
6HE1-TC1
F 019 Z10 364 
8943942920 
INJECTION-PUMP ASSEMBLY
6HE1-TC1
F 019 Z10 365 
8943942921 
INJECTION-PUMP ASSEMBLY
6HE1-TC1
9 400 615 254 
8943942922 
INJECTION-PUMP ASSEMBLY
6HE1-TC1
9 400 615 255 
1156029090 
INJECTION-PUMP ASSEMBLY
6BG1-MTC
9 400 615 256 
1156029110 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 613 468 
1156029080 
INJECTION-PUMP ASSEMBLY
6SD1
 
8943951110 
INJECTION-PUMP ASSEMBLY
6HE1-N
9 400 613 226 
8943951111 
INJECTION-PUMP ASSEMBLY
6HE1-N