Rating:
Information injection-pump assembly
BOSCH
9 400 617 030
9400617030
ZEXEL
106671-8920
1066718920
HINO
220801760A
220801760a
Cross reference number
BOSCH
9 400 617 030
9400617030
ZEXEL
106671-8920
1066718920
HINO
220801760A
220801760a
Zexel num
Bosch num
Firm num
Name
9 400 617 030
220801760A HINO
INJECTION-PUMP ASSEMBLY
A K 14CA INJECTION PUMP ASSY PE6P,6PD PE
A K 14CA INJECTION PUMP ASSY PE6P,6PD PE
9 400 617 030
220801760B HINO
INJECTION-PUMP ASSEMBLY
B K 14CA INJECTION PUMP ASSY PE6P,6PD PE
B K 14CA INJECTION PUMP ASSY PE6P,6PD PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
134424-4420
Overflow valve opening pressure
kPa
162
147
177
Overflow valve opening pressure
kgf/cm2
1.65
1.5
1.8
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3.9
3.84
3.9
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.75 60.25
Cal 1-4 deg. 60 59.75 60.25
Difference between angles 2
Cyl.1-2 deg. 120 119.75 120.25
Cyl.1-2 deg. 120 119.75 120.25
Difference between angles 3
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 4
Cal 1-3 deg. 240 239.75 240.25
Cal 1-3 deg. 240 239.75 240.25
Difference between angles 5
Cal 1-5 deg. 300 299.75 300.25
Cal 1-5 deg. 300 299.75 300.25
Injection quantity adjustment
Adjusting point
A
Rack position
10.9
Pump speed
r/min
550
550
550
Average injection quantity
mm3/st.
216
214
218
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Boost pressure
kPa
61.3
61.3
Boost pressure
mmHg
460
460
Injection quantity adjustment_02
Adjusting point
B
Rack position
10.55
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
203
200
206
Max. variation between cylinders
%
0
-5
5
Fixing the lever
*
Boost pressure
kPa
61.3
61.3
Boost pressure
mmHg
460
460
Injection quantity adjustment_03
Adjusting point
C
Rack position
10.65+-0
.5
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
201
198
204
Fixing the lever
*
Boost pressure
kPa
61.3
61.3
Boost pressure
mmHg
460
460
Injection quantity adjustment_04
Adjusting point
D
Rack position
3.5+-0.5
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
10.5
7.5
13.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Injection quantity adjustment_05
Adjusting point
E
Rack position
11.9+-0.
1
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
230
225
235
Fixing the lever
*
Boost pressure
kPa
61.3
61.3
Boost pressure
mmHg
460
460
Rack limit
*
Injection quantity adjustment_06
Adjusting point
L
Rack position
3.4+-0.5
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
10.5
7.5
13.5
Fixing the lever
*
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Boost compensator adjustment
Pump speed
r/min
550
550
550
Rack position
(7.8)
Boost pressure
kPa
13.3
13.3
15.3
Boost pressure
mmHg
100
100
115
Boost compensator adjustment_02
Pump speed
r/min
550
550
550
Rack position
10.9
Boost pressure
kPa
48
48
48
Boost pressure
mmHg
360
360
360
Timer adjustment
Pump speed
r/min
700--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
650
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1000
Advance angle
deg.
4
3.7
4.3
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Lever ratio: RT
(2)Target shim dimension: TH
(3)Tolerance for racks not indicated: +-0.05mm.
(4)Stop lever setting: R1
(5)RACK LIMIT
(6)Boost compensator stroke: BCL
(7)Damper spring setting
(8)Variable speed specification: idling adjustment
(9)Fix the lever at the full-load position at delivery.
(10)Main spring setting
----------
RT=1 TH=2.2mm R1=(12.1)+0.5mm BCL=(3.1)mm
----------
----------
RT=1 TH=2.2mm R1=(12.1)+0.5mm BCL=(3.1)mm
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Use the hole at R = aa
(2)Stopper bolt setting
(3)Set the stopper bolt (fixed at full-load position at delivery.)
----------
aa=130mm
----------
a=(13deg)+-5deg b=(1deg)+-5deg
----------
aa=130mm
----------
a=(13deg)+-5deg b=(1deg)+-5deg
0000000901
F:Full load
I:Idle
(1)Stopper bolt setting
(2)Use the hole at R = aa
----------
aa=45mm
----------
a=25deg+-5deg b=38deg+-3deg
----------
aa=45mm
----------
a=25deg+-5deg b=38deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Set the stopper screw at rack position = aa before governor adjustment. (After setting, apply red paint.)
(2)Use the hole at R = bb
----------
aa=(12.1)+0.5mm bb=36mm
----------
a=35deg+-5deg b=39deg+-5deg
----------
aa=(12.1)+0.5mm bb=36mm
----------
a=35deg+-5deg b=39deg+-5deg
0000001201
(1)Minimum - maximum speed specification
(2)Variable speed specification
(3)Use the hole at R = aa
----------
aa=112mm
----------
a=(18.5deg)+-5deg b=(17.5deg)
----------
aa=112mm
----------
a=(18.5deg)+-5deg b=(17.5deg)
0000001501 LEVER
2-stage changeover lever adjustment
(A) Speed lever
(B) Load lever
(C) 2-stage changeover lever
(D) Link
(E) Bolt
(G) Variable speed specifications
(H) Minimum maximum speed specifications
F:Full speed
I:Idle
1. Minimum-maximum speed specification adjustment (when running)
(1)After completing governor adjustment, hold the 2-stage changeover lever (C) so that the speed lever (A) contacts the full speed stopper.
(2)In this condition, the load lever is held in the idle position.
(3)Adjust bolt (E) so that the clearance between the pin underneath lever (C) and the end of the long groove in link (D) is L.
(4)Lock using the nut.
2. Variable speed specification adjustment (at operation)
(1)Hold the 2-stage changeover lever (C) so that the load lever (B) contacts the full load stopper. (When the load lever is equipped with a cancel mechanism, move it so that it contacts the stopper without canceling.)
(2)In this condition, confirm that the speed lever (A) moves from idle to full speed.
----------
L=1~2mm
----------
----------
L=1~2mm
----------
Timing setting
(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(0deg)
----------
----------
a=(0deg)