101603-8800 ZEXEL 9 400 615 280 BOSCH INJECTION-PUMP ASSEMBLY 9400615280 1016038800 1156030360


101603-8800 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 101603-8800 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 615 280 9400615280
ZEXEL 101603-8800 1016038800
ISUZU 1156030360 1156030360

Service parts 101603-8800 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-3880
3. GOVERNOR 105921-8230
4. SUPPLY PUMP 105210-6540
5. AUTOM. ADVANCE MECHANIS 105643-0650
6. COUPLING PLATE 105662-1560
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-6301
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 22.1(225)
13. NOZZLE-HOLDER 105030-4351
14. NOZZLE 105015-8640
15. NOZZLE SET

Include in #1:

101603-8800 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

BOSCH 9 400 615 280 9400615280
ZEXEL 101603-8800 1016038800
ISUZU 1156030360 1156030360


Zexel num
Bosch num
Firm num
Name
101603-8800 
9 400 615 280 
1156030360  ISUZU
INJECTION-PUMP ASSEMBLY
6SD1 K 14BF INJECTION PUMP ASSY PE6AD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.7 3.65 3.75
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.9
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   89.8 88.2 91.4
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   11.2 9.2 13.2
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.9)
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   89.8 88.8 90.8
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   88 88 93
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   550--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   500
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1250
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-8800
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=K80
----------

Speed control lever angle

Test data 101603-8800
F:Full speed I:Idle (1)Use the pin at R = aa (2)Stopper bolt set position 'H'
----------
aa=35.5mm
----------
a=18deg+-5deg b=36deg+-3deg

Stop lever angle

Test data 101603-8800
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=45mm
----------
a=25deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101603-8800
(A) Housing (B) Snap ring (C) adjusting screw (D) Set screw (E): Push rod (F) Spacer 1. Adjustment of the aneroid compensator (1)Adjust with the (D) set screw so that the clearance between the (A) housing and (B) snap ring is L1. (2)Select the push rod (E) so that the distance from the end surface of the (F) spacer becomes L2. (3)(C) Turn the screw to adjust the beginning of aneroid compensator operation. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Adjust using screw C to obtain the performance shown in the graph above. (3)After final adjustment, confirm that the gap between housing (A) and snapring (B) is L3.
----------
N1=650r/min L1=1.4~1.7mm L2=0.5+-0.5mm L3=0.1~0.5mm
----------
Ra=R1(11.9)mm Rb=(R1-0.95)mm Pa=89.8+-2.7kPa(674+-20mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=89.8+-1cm3/1000st Q2=67.5+-1.6cm3/1000st

Timing setting

Test data 101603-8800
(1)Pump vertical direction (2)Position of timer's threaded hole at the No. 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=18deg
----------
a=(40deg)




Have questions with 101603-8800?





Group cross 101603-8800 ZEXEL

Isuzu 

101603-8800  
9 400 615 280 
1156030360 
INJECTION-PUMP ASSEMBLY
6SD1
9 400 610 676 
1156030380 
INJECTION-PUMP ASSEMBLY
6SA1
 
8943958120 
INJECTION-PUMP ASSEMBLY
6HH1-N
9 400 610 677 
8943958121 
INJECTION-PUMP ASSEMBLY
6HH1-N
 
8943900810 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 610 678 
8943900811 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 610 679 
8943958131 
INJECTION-PUMP ASSEMBLY
6HH1-S
9 400 610 680 
1156031400 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 610 681 
8943909610 
INJECTION-PUMP ASSEMBLY
6HH1
 
8943909611 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 615 281 
8943909612 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 610 682 
8943909290 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 610 683 
8943909300 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 615 282 
8943910410 
INJECTION-PUMP ASSEMBLY
6HH1-S
Back to top