Rating:
Information injection-pump assembly
BOSCH
F 019 Z10 147
f019z10147
ZEXEL
101322-0110
1013220110
ISUZU
5156004853
5156004853
Service parts 101322-0110 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
8.
_
9.
_
10.
NOZZLE AND HOLDER ASSY
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
11.8{120}
15.
NOZZLE SET
Cross reference number
BOSCH
F 019 Z10 147
f019z10147
ZEXEL
101322-0110
1013220110
ISUZU
5156004853
5156004853
Zexel num
Bosch num
Firm num
Name
101322-0110
F 019 Z10 147
5156004853 ISUZU
INJECTION-PUMP ASSEMBLY
3AA1 * K
3AA1 * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-3-2
Pre-stroke
mm
1.75
1.7
1.8
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 2
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Injection quantity adjustment
Adjusting point
A
Rack position
12.5
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
36.8
33.8
39.8
Max. variation between cylinders
%
0
-4
4
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
13.6
Pump speed
r/min
850
850
850
Average injection quantity
mm3/st.
40.4
38.7
42.1
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
7.7+-0.5
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
8
6.9
9.1
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)At rack cap installation: R1
----------
K=8 R1=(17.5)mm
----------
----------
K=8 R1=(17.5)mm
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
----------
----------
a=18deg+-5deg b=34deg+-5deg c=32deg+-3deg
----------
----------
a=18deg+-5deg b=34deg+-5deg c=32deg+-3deg
Have questions with 101322-0110?
Group cross 101322-0110 ZEXEL
Isuzu
101322-0110
F 019 Z10 147
5156004853
INJECTION-PUMP ASSEMBLY
3AA1
3AA1