Rating:
Information injection-pump assembly
BOSCH
9 400 617 784
9400617784
ZEXEL
106691-3070
1066913070
HINO
220004210A
220004210a
Service parts 106691-3070 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
23600-1680
12.
Open Pre:MPa(Kqf/cm2)
21.6{220}
15.
NOZZLE SET
Include in #1:
106691-3070
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 400 617 784
9400617784
ZEXEL
106691-3070
1066913070
HINO
220004210A
220004210a
Zexel num
Bosch num
Firm num
Name
106691-3070
9 400 617 784
220004210A HINO
INJECTION-PUMP ASSEMBLY
ER200 * K 14CA INJECTION PUMP ASSY PE6P,6PD PE
ER200 * K 14CA INJECTION PUMP ASSY PE6P,6PD PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
134424-0920
Overflow valve opening pressure
kPa
177
143
211
Overflow valve opening pressure
kgf/cm2
1.8
1.45
2.15
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3.45
3.42
3.48
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.75 60.25
Cal 1-4 deg. 60 59.75 60.25
Difference between angles 2
Cyl.1-2 deg. 120 119.75 120.25
Cyl.1-2 deg. 120 119.75 120.25
Difference between angles 3
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 4
Cal 1-3 deg. 240 239.75 240.25
Cal 1-3 deg. 240 239.75 240.25
Difference between angles 5
Cal 1-5 deg. 300 299.75 300.25
Cal 1-5 deg. 300 299.75 300.25
Injection quantity adjustment
Adjusting point
B
Rack position
8.9
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
112
110
114
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Remarks
(check)
(check)
Injection quantity adjustment_02
Adjusting point
C
Rack position
8.9
Pump speed
r/min
1150
1150
1150
Average injection quantity
mm3/st.
120
117
123
Max. variation between cylinders
%
0
-4
4
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
D
Rack position
4.5+-0.5
Pump speed
r/min
225
225
225
Average injection quantity
mm3/st.
11
8
14
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Injection quantity adjustment_04
Adjusting point
E
Rack position
8.9+0.2
Pump speed
r/min
330
330
330
Average injection quantity
mm3/st.
97
94
100
Fixing the lever
*
Remarks
After startup boost setting
After startup boost setting
Injection quantity adjustment_05
Adjusting point
F
Rack position
14.4+-0.
5
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
187
187
207
Fixing the lever
*
Remarks
After startup boost setting
After startup boost setting
Timer adjustment
Pump speed
r/min
975--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
925
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1050
Advance angle
deg.
1.4
0.9
1.9
Timer adjustment_04
Pump speed
r/min
1150
Advance angle
deg.
3.25
2.95
3.55
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)After completing adjustment of the broken line, set the lever at the unbroken line position.
(2)Rack limit using stop lever
(3)Excess fuel setting for starting: SXL
(4)Beginning of damper spring operation: DL
----------
SXL=8.9+0.2mm DL=2.4-0.2mm
----------
----------
SXL=8.9+0.2mm DL=2.4-0.2mm
----------
0000000901
F:Full load
I:Idle
(1)Stopper bolt setting
----------
----------
a=86deg+-5deg b=18deg+-3deg
----------
----------
a=86deg+-5deg b=18deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=10deg+-5deg b=44deg+-5deg
----------
----------
a=10deg+-5deg b=44deg+-5deg
0000001501 MICRO SWITCH
Switch adjustment
Adjust the bolt so that the lower lever position is obtained when the switch is turned ON.
(1)Speed N1
(2)Rack position Ra
----------
N1=300+25r/min Ra=4.5mm
----------
----------
N1=300+25r/min Ra=4.5mm
----------
Have questions with 106691-3070?
Group cross 106691-3070 ZEXEL
Hino
Hino
106691-3070
9 400 617 784
220004210A
INJECTION-PUMP ASSEMBLY
ER200
ER200