Rating:
Information injection-pump assembly
BOSCH
9 400 611 720
9400611720
ZEXEL
106676-2150
1066762150
MITSUBISHI
ME158668
me158668
Service parts 106676-2150 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
ME158263
12.
Open Pre:MPa(Kqf/cm2)
17.7{180}/21.6{220}
14.
NOZZLE
Include in #1:
106676-2150
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 400 611 720
9400611720
ZEXEL
106676-2150
1066762150
MITSUBISHI
ME158668
me158668
Zexel num
Bosch num
Firm num
Name
106676-2150
9 400 611 720
ME158668 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D24-T K 14CA INJECTION PUMP ASSY PE6P,6PD PE
6D24-T K 14CA INJECTION PUMP ASSY PE6P,6PD PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
131424-4620
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
4.8
4.75
4.85
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
-
Rack position
8.7
Pump speed
r/min
1100
1100
1100
Each cylinder's injection qty
mm3/st.
114.5
111.1
117.9
Basic
*
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_02
Adjusting point
C
Rack position
5.2+-0.5
Pump speed
r/min
425
425
425
Each cylinder's injection qty
mm3/st.
9
7.6
10.4
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_03
Adjusting point
A
Rack position
R1(8.7)
Pump speed
r/min
1100
1100
1100
Average injection quantity
mm3/st.
114.5
112.5
116.5
Basic
*
Fixing the lever
*
Boost pressure
kPa
14
14
Boost pressure
mmHg
105
105
Injection quantity adjustment_04
Adjusting point
B
Rack position
R2(R1+0.
3)
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
114.5
108.5
120.5
Fixing the lever
*
Boost pressure
kPa
14
14
Boost pressure
mmHg
105
105
Injection quantity adjustment_05
Adjusting point
E
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
100
60
140
Fixing the lever
*
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Boost compensator adjustment
Pump speed
r/min
500
500
500
Rack position
R2-0.3
Boost pressure
kPa
3.3
3.3
5.3
Boost pressure
mmHg
25
25
40
Boost compensator adjustment_02
Pump speed
r/min
500
500
500
Rack position
R2(R1+0.
3)
Boost pressure
kPa
5.3
5.3
7.3
Boost pressure
mmHg
40
40
55
Timer adjustment
Pump speed
r/min
0
Advance angle
deg.
2.5
2
3
Timer adjustment_02
Pump speed
r/min
300
Advance angle
deg.
2.5
2
3
Remarks
Start
Start
Timer adjustment_03
Pump speed
r/min
-
Advance angle
deg.
0
0
0
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Tolerance for racks not indicated: +-0.05mm.
(2)Boost compensator cancel stroke: BSL
(3)Set the governor spring.
(4)Damper spring setting
(5)Boost compensator stroke: BCL
----------
BSL=1.6mm BCL=0.3+-0.1mm
----------
----------
BSL=1.6mm BCL=0.3+-0.1mm
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=19deg+-5deg b=16deg+-5deg
----------
----------
a=19deg+-5deg b=16deg+-5deg
0000000901
F:Full load
I:Idle
(1)Stopper bolt setting
(2)At rack = aa, speed = bb
----------
aa=7.3mm bb=600r/min
----------
a=5deg+-5deg b=7deg+-3deg
----------
aa=7.3mm bb=600r/min
----------
a=5deg+-5deg b=7deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Rack position = aa
(2)Stopper bolt setting
(3)Use the hole at R = bb
(4)Rack position = cc or less (Confirm non-injection)
(5)Stopper bolt setting
(6)Set the stopper bolt at the lever angle.
----------
aa=(15.3)mm bb=20mm cc=3.2mm
----------
a=2deg+-5deg b=40deg+-5deg
----------
aa=(15.3)mm bb=20mm cc=3.2mm
----------
a=2deg+-5deg b=40deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=12deg
----------
a=(6deg)
----------
aa=12deg
----------
a=(6deg)
Have questions with 106676-2150?
Group cross 106676-2150 ZEXEL
Mitsubishi
Mitsubishi
Mitsubishi
106676-2150
9 400 611 720
ME158668
INJECTION-PUMP ASSEMBLY
6D24-T
6D24-T