106671-6780 ZEXEL F 019 Z10 798 BOSCH INJECTION-PUMP ASSEMBLY f019z10798 1066716780


106671-6780 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 106671-6780 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 019 Z10 798 f019z10798
ZEXEL 106671-6780 1066716780

Service parts 106671-6780 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-6701
3. GOVERNOR 105960-0500
4. SUPPLY PUMP 105237-4731
5. AUTOM. ADVANCE MECHANIS 105681-2920
6. COUPLING PLATE 105664-2670
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-8201
11. Nozzle and Holder 1-15300-413-0
12. Open Pre:MPa(Kqf/cm2) 17.7(180)/22.1(225)
13. NOZZLE-HOLDER 105041-4371
14. NOZZLE
15. NOZZLE SET 105019-2730

Include in #1:

106671-6780 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH F 019 Z10 798 f019z10798
ZEXEL 106671-6780 1066716780


Zexel num
Bosch num
Firm num
Name
106671-6780 
F 019 Z10 798 
   
INJECTION-PUMP ASSEMBLY
6WG1-TQD 14CA INJECTION PUMP ASSY PE6P,6PD PE
106671-6780 
F 019 Z10 798 
8980122410  ISUZU
INJECTION-PUMP ASSEMBLY
6WG1-TQD K 14CA INJECTION PUMP ASSY PE6P,6PD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-4320
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED4 control unit part number   407915-0 590
RED4 rack sensor specifications mm   19
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.9 3.87 3.93
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Rack position   (11.2)
PWM %   51
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   182 180 184
Max. variation between cylinders %   0 -3 3
Basic   *
Injection quantity adjustment_02
Rack position   (7)
PWM %   27.5+-2. 8
Pump speed r/min   475 475 475
Average injection quantity mm3/st.   15.5 12.3 18.7
Max. variation between cylinders %   0 -13 13
Governor adjustment
Pump speed r/min   550--
Advance angle deg.   0 0 0
Remarks
Start
 
Governor adjustment_02
Pump speed r/min   500
Advance angle deg.   0 -0.5 0
Governor adjustment_03
Pump speed r/min   650-50
Advance angle deg.   -1.25 -1.75 -0.75
Remarks
Finish
 

Test data Ex:

Speed control lever angle

Test data 106671-6780
N:Pump normal S:Stop the pump. (1)R = aa (2)R = bb
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg

0000000901

Test data 106671-6780
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=23deg
----------
a=(90deg)

Stop lever angle

Test data 106671-6780
(PWM) Pulse width modulation (%) (R) Rack position (mm) Rack sensor output characteristics 1. Rack limit adjustment (1)Measure the rack position R2 for PWM a2%. (2)Confirm that it is within the range R2 = 15+-1 mm. (3)Measure the rack position R1 at PWM a %. (4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm. 2. Check the limp home operation. (1)Move the switch box's limp home switch to the limp home side. (2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table. 3. Check the pull down operation. (1)Confirm that the rack position is 19 mm at PWM B%. (2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5 % B=95%
----------




Have questions with 106671-6780?





Group cross 106671-6780 ZEXEL

Isuzu 

9 400 613 266 
1156034840 
INJECTION-PUMP ASSEMBLY
6HK1-XQB
9 400 613 267 
1156034870 
INJECTION-PUMP ASSEMBLY
6WG1-T
9 400 613 268 
1156034910 
INJECTION-PUMP ASSEMBLY
6HK1-XQS
9 400 613 301 
1156034940 
INJECTION-PUMP ASSEMBLY
6SD1-XQB
F 01G 09U 0JA 
1156034941 
INJECTION-PUMP ASSEMBLY
6SD1-XQB
9 400 613 302 
1156034950 
INJECTION-PUMP ASSEMBLY
6SD1-X
9 400 613 231 
1156035000 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 613 441 
1156035002 
INJECTION-PUMP ASSEMBLY
6HK1-T
F 019 Z10 235 
1156035003 
INJECTION-PUMP ASSEMBLY
6HK1-T
F 01G 09U 1F4 
1156035004 
INJECTION-PUMP ASSEMBLY
6HK1TQC
9 400 616 920 
1156035030 
INJECTION-PUMP ASSEMBLY
6WG1-X
9 400 619 942 
1156035110 
INJECTION-PUMP ASSEMBLY
6HK1-T
106671-6780  
F 019 Z10 798 
 
INJECTION-PUMP ASSEMBLY
6WG1-TQD

Isuzu 

106671-6780  
F 019 Z10 798 
8980122410 
INJECTION-PUMP ASSEMBLY
6WG1-TQD
 
8980769960 
INJECTION-PUMP ASSEMBLY
6HK1M
Back to top