Rating:
Information injection-pump assembly
BOSCH
F 019 Z10 798
f019z10798
ZEXEL
106671-6780
1066716780
Service parts 106671-6780 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
1-15300-413-0
12.
Open Pre:MPa(Kqf/cm2)
17.7(180)/22.1(225)
14.
NOZZLE
Include in #1:
106671-6780
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
F 019 Z10 798
f019z10798
ZEXEL
106671-6780
1066716780
Zexel num
Bosch num
Firm num
Name
106671-6780
F 019 Z10 798
INJECTION-PUMP ASSEMBLY
6WG1-TQD 14CA INJECTION PUMP ASSY PE6P,6PD PE
6WG1-TQD 14CA INJECTION PUMP ASSY PE6P,6PD PE
106671-6780
F 019 Z10 798
8980122410 ISUZU
INJECTION-PUMP ASSEMBLY
6WG1-TQD K 14CA INJECTION PUMP ASSY PE6P,6PD PE
6WG1-TQD K 14CA INJECTION PUMP ASSY PE6P,6PD PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
134424-4320
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
255
255
255
Tester oil delivery pressure
kgf/cm2
2.6
2.6
2.6
RED4 control unit part number
407915-0
590
RED4 rack sensor specifications
mm
19
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.9
3.87
3.93
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.75 60.25
Cal 1-5 deg. 60 59.75 60.25
Difference between angles 2
Cal 1-3 deg. 120 119.75 120.25
Cal 1-3 deg. 120 119.75 120.25
Difference between angles 3
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 4
Cyl.1-2 deg. 240 239.75 240.25
Cyl.1-2 deg. 240 239.75 240.25
Difference between angles 5
Cal 1-4 deg. 300 299.75 300.25
Cal 1-4 deg. 300 299.75 300.25
Injection quantity adjustment
Rack position
(11.2)
PWM
%
51
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
182
180
184
Max. variation between cylinders
%
0
-3
3
Basic
*
Injection quantity adjustment_02
Rack position
(7)
PWM
%
27.5+-2.
8
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
15.5
12.3
18.7
Max. variation between cylinders
%
0
-13
13
Governor adjustment
Pump speed
r/min
550--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Governor adjustment_02
Pump speed
r/min
500
Advance angle
deg.
0
-0.5
0
Governor adjustment_03
Pump speed
r/min
650-50
Advance angle
deg.
-1.25
-1.75
-0.75
Remarks
Finish
Finish
Test data Ex:
Speed control lever angle
N:Pump normal
S:Stop the pump.
(1)R = aa
(2)R = bb
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg
0000000901
(1)Pump vertical direction
(2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=23deg
----------
a=(90deg)
----------
aa=23deg
----------
a=(90deg)
Stop lever angle
(PWM) Pulse width modulation (%)
(R) Rack position (mm)
Rack sensor output characteristics
1. Rack limit adjustment
(1)Measure the rack position R2 for PWM a2%.
(2)Confirm that it is within the range R2 = 15+-1 mm.
(3)Measure the rack position R1 at PWM a %.
(4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm.
2. Check the limp home operation.
(1)Move the switch box's limp home switch to the limp home side.
(2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table.
3. Check the pull down operation.
(1)Confirm that the rack position is 19 mm at PWM B%.
(2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5 % B=95%
----------
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5 % B=95%
----------
Have questions with 106671-6780?
Group cross 106671-6780 ZEXEL
Isuzu
106671-6780
F 019 Z10 798
INJECTION-PUMP ASSEMBLY
6WG1-TQD
6WG1-TQD
Isuzu
106671-6780
F 019 Z10 798
8980122410
INJECTION-PUMP ASSEMBLY
6WG1-TQD
6WG1-TQD