Rating:
Information injection-pump assembly
ZEXEL
106671-2550
1066712550
MITSUBISHI
ME056252
me056252
Service parts 106671-2550 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
30961-20010
12.
Open Pre:MPa(Kqf/cm2)
21.6{220}
15.
NOZZLE SET
Include in #1:
106671-2550
as INJECTION-PUMP ASSEMBLY
Cross reference number
ZEXEL
106671-2550
1066712550
MITSUBISHI
ME056252
me056252
Zexel num
Bosch num
Firm num
Name
106671-2550
ME056252 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D22 * K
6D22 * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
4.8
4.75
4.85
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
-
Rack position
7.5
Pump speed
r/min
700
700
700
Each cylinder's injection qty
mm3/st.
93
90.4
95.6
Basic
*
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_02
Adjusting point
E
Rack position
5+-0.5
Pump speed
r/min
500
500
500
Each cylinder's injection qty
mm3/st.
16.5
14
19
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_03
Adjusting point
A
Rack position
R1(7.5)
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
93
92
94
Fixing the lever
*
Injection quantity adjustment_04
Adjusting point
B
Rack position
R1(7.5)
Pump speed
r/min
1100
1100
1100
Average injection quantity
mm3/st.
107
103
111
Difference in delivery
mm3/st.
8
8
8
Fixing the lever
*
Injection quantity adjustment_05
Adjusting point
C
Rack position
5.7+-0.5
Pump speed
r/min
200
200
200
Each cylinder's injection qty
mm3/st.
16.5
14
19
Fixing the rack
*
Remarks
(check)
(check)
Injection quantity adjustment_06
Adjusting point
F
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
115
95
135
Fixing the lever
*
Timer adjustment
Pump speed
r/min
1000--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
950
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1050
Advance angle
deg.
2
1.5
2.5
Timer adjustment_04
Pump speed
r/min
1150
Advance angle
deg.
4
3.5
4.5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Beginning of damper spring operation: DL
(2)Excess fuel setting for starting: SXL
----------
DL=4.5-0.2mm SXL=R1+0.2mm
----------
----------
DL=4.5-0.2mm SXL=R1+0.2mm
----------
Speed control lever angle
F:Full speed
----------
----------
a=28deg+-5deg
----------
----------
a=28deg+-5deg
0000000901
F:Full load
I:Idle
(1)Stopper bolt setting
----------
----------
a=21.5deg+-5deg b=24deg+-3deg
----------
----------
a=21.5deg+-5deg b=24deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=25deg+-5deg b=64deg+-5deg
----------
----------
a=25deg+-5deg b=64deg+-5deg
0000001501 MICRO SWITCH
Adjustment of the micro-switch
Adjust the bolt to obtain the following lever position when the micro-switch is ON.
(1)Speed N1
(2)Rack position Ra
----------
N1=325+-5r/min Ra=5.4mm
----------
----------
N1=325+-5r/min Ra=5.4mm
----------
0000001601 RACK SENSOR
V1:Output voltage
Vf:Full side output voltage
(A) Load lever
(B) Nut
(c) Nut
(F) Full
(P) Potentiometer
1. Load sensor adjustment
(1)Apply DC24V to between the potentiometer (P)'s connector terminals (1) ~ (3) and measure the output voltage between (1) ~ (2).
(2)Position the load lever (A) against the full side stopper bolt and turn the nut (B) to adjust the potentiometer (P)'s output voltage to Vf.
(3)Confirm that the load lever (A) moves smoothly between full and idle and then tighten nut (C).
(Tightening torque: 4.4 - 7 N.m {0.5 - 0.7 kgf.m})
(4)Hold the load lever (A) several times against the full side stopper bolt and confirm potentiometer (P)'s output voltage Vf.
----------
Vf=1.6+-0.1V
----------
----------
Vf=1.6+-0.1V
----------
Have questions with 106671-2550?
Group cross 106671-2550 ZEXEL
Mitsubishi
Mitsubishi-Heav
Mitsubishi
106671-2550
ME056252
INJECTION-PUMP ASSEMBLY
6D22
6D22