Rating:
Information injection-pump assembly
BOSCH
F 019 Z10 026
f019z10026
ZEXEL
106671-2020
1066712020
MITSUBISHI
3096198021
3096198021
Service parts 106671-2020 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
30961-99090
12.
Open Pre:MPa(Kqf/cm2)
21.6{220}
15.
NOZZLE SET
Include in #1:
106671-2020
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
F 019 Z10 026
f019z10026
ZEXEL
106671-2020
1066712020
MITSUBISHI
3096198021
3096198021
Zexel num
Bosch num
Firm num
Name
106671-2020
F 019 Z10 026
3096198021 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D20MT * K
6D20MT * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105100-4140
Nozzle
105015-3710
Nozzle holder
105031-3520
Opening pressure
MPa
21.6
Opening pressure
kgf/cm2
220
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-700
Outer diameter - inner diameter - length (mm) mm 6-2-700
Overflow valve
131424-1520
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
4.8
4.75
4.85
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
11.2
Pump speed
r/min
980
980
980
Average injection quantity
mm3/st.
158
153.5
162.5
Max. variation between cylinders
%
0
-4
4
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
11.2
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
157.5
154.5
160.5
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
5.6+-0.5
Pump speed
r/min
225
225
225
Average injection quantity
mm3/st.
17.5
14.9
20.1
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Timer adjustment
Pump speed
r/min
750+100
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
1000
Advance angle
deg.
1.7
1.2
2.2
Timer adjustment_03
Pump speed
r/min
1250
Advance angle
deg.
4
3.5
4.5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)RACK LIMIT: RAL
(3)Idle sub spring setting: L1.
----------
K=18 RAL=12+0.2mm L1=5-0.5mm
----------
----------
K=18 RAL=12+0.2mm L1=5-0.5mm
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
----------
----------
a=13deg+-5deg b=28deg+-5deg c=32deg+-3deg
----------
----------
a=13deg+-5deg b=28deg+-5deg c=32deg+-3deg
Have questions with 106671-2020?
Group cross 106671-2020 ZEXEL
Mitsubishi-Heav
Mitsubishi
106671-2020
F 019 Z10 026
3096198021
INJECTION-PUMP ASSEMBLY
6D20MT
6D20MT