Rating:
Information injection-pump assembly
ZEXEL
104745-0141
1047450141
MAZDA
W91713800A
w91713800a
Cross reference number
ZEXEL
104745-0141
1047450141
MAZDA
W91713800A
w91713800a
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105780-0060
Bosch type code
NP-DN0SD1510
Nozzle holder
105780-2150
Opening pressure
MPa
13
13
13.3
Opening pressure
kgf/cm2
133
133
136
Injection pipe
157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-450
Inside diameter - outside diameter - length (mm) mm 2-6-450
Joint assembly
157641-4720
Tube assembly
157641-4020
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
57.3
56.8
57.8
Difference in delivery
mm3/st.
4.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_02
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
52
48.5
55.5
Oil temperature
degC
48
46
50
Injection timing adjustment_03
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
57.3
56.3
58.3
Difference in delivery
mm3/st.
5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_04
Pump speed
r/min
2000
2000
2000
Average injection quantity
mm3/st.
55.3
51.8
58.8
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
2450
2450
2450
Average injection quantity
mm3/st.
22.9
19.9
25.9
Difference in delivery
mm3/st.
4.5
Basic
*
Oil temperature
degC
55
52
58
Injection quantity adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
8
Oil temperature
degC
55
52
58
Injection quantity adjustment_03
Pump speed
r/min
2450
2450
2450
Average injection quantity
mm3/st.
22.9
12.9
32.9
Difference in delivery
mm3/st.
5
Basic
*
Oil temperature
degC
55
52
58
Governor adjustment
Pump speed
r/min
360
360
360
Average injection quantity
mm3/st.
10.8
9.8
11.8
Difference in delivery
mm3/st.
1.7
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
360
360
360
Average injection quantity
mm3/st.
10.8
9.3
12.3
Difference in delivery
mm3/st.
2.2
Basic
*
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
150
150
150
Average injection quantity
mm3/st.
70
55
90
Basic
*
Oil temperature
degC
48
46
50
Remarks
Full
Full
Timer adjustment_02
Pump speed
r/min
150
150
150
Average injection quantity
mm3/st.
70
50
90
Oil temperature
degC
48
46
50
Remarks
Full
Full
Speed control lever angle
Pump speed
r/min
360
360
360
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
1500
1500
1500
Overflow quantity
cm3/min
440
310
570
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
1500
1500
1500
Pressure
kPa
618
589
647
Pressure
kgf/cm2
6.3
6
6.6
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
1500
1500
1500
Pressure
kPa
618
579
657
Pressure
kgf/cm2
6.3
5.9
6.7
Basic
*
Oil temperature
degC
50
48
52
0000001101
Pump speed
r/min
1500
1500
1500
Timer stroke
mm
7.4
7.2
7.6
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
500
500
500
Timer stroke
mm
0.9
0.1
1.7
Oil temperature
degC
48
46
50
_03
Pump speed
r/min
1500
1500
1500
Timer stroke
mm
7.4
7
7.8
Basic
*
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
1750
1750
1750
Timer stroke
mm
8.9
8.1
9.7
Oil temperature
degC
50
48
52
_05
Pump speed
r/min
2100
2100
2100
Timer stroke
mm
9.8
8.8
10.6
Oil temperature
degC
52
50
54
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
44.7
44.2
45.2
Timer stroke TA
mm
6.7
6.7
6.7
Timer stroke variation dT
mm
0.7
0.5
0.9
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
44.7
43.7
45.7
Timer stroke TA
mm
6.7
6.7
6.7
Timer stroke variation dT
mm
0.7
0.3
1.1
Basic
*
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
38.7
37.2
40.2
Timer stroke TA
mm
6.1
6.1
6.1
Timer stroke variation dT
mm
1.3
0.7
1.9
Oil temperature
degC
50
48
52
0000001501
Pump speed
r/min
2000
2000
2000
Height
m
1560
1560
1560
Atmospheric pressure difference
kPa
-16.7
-16.7
-16.7
Atmospheric pressure difference
mmHg
-125
-125
-125
Average injection quantity
mm3/st.
49.9
49.4
50.4
Decrease qty
mm3/st.
5.4
5.4
5.4
Decrease rate
%
10
10
10
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
2000
2000
2000
Atmospheric pressure difference
kPa
-5.9
-5.9
-5.9
Atmospheric pressure difference
mmHg
-44
-69
-19
Average injection quantity
mm3/st.
55.3
50.3
57.8
Decrease rate
%
0
0
0
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
2000
2000
2000
Atmospheric pressure difference
kPa
-16.7
-16.7
-16.7
Atmospheric pressure difference
mmHg
-125
-125
-125
Average injection quantity
mm3/st.
49.9
48.9
50.9
Decrease rate
%
10
10
10
Basic
*
Oil temperature
degC
50
48
52
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
6.01
5.91
6.11
MS dimension
mm
0.9
0.8
1
Pre-stroke
mm
0.03
0.01
0.05
Control lever angle alpha
deg.
12.5
8.5
16.5
Control lever angle beta
deg.
40
37
43
Test data Ex:
0000001801 CONTROL STANDARD AT IDLING
Standards for idle difference in delivery control
After idle adjustment, measure the idle injection quantities of (A) to (D).
Install the colored rings to the delivery valve holders (A) to (D) in accordance with the table.
(A): A cylinder (B) :B cylinder (C) : C cylinder (D): D cylinder
(E): Collar ring
(F): (A) >= (C)
(G): (C) > (A)
(H): (A) - (C) or (C) - (A)
(I): 0.2, 0.1(mm3/st)
(J): (B) - (D) or (D) - (B)
(K): Ring color
(L): At least 0.6 mm3/st
(M): 0.3, 0.4, 0.5 (mm3/st)
(N): 0.2, 0.1, 0.0 (mm3/st)
(O): (B) >= (D)
(P): (D) > (B)
(T): Yellow
(U): White
(V): Red
----------
----------
----------
----------
0000001901 WIRE
Confirmation of the wire length:
Accelerator wire: Idle-full stroke: L1
Adjustment of the double stage actuator:
(1)Apply negative pressure P1 {P2} to the actuator through the negative pressure inlet port (A).
(2)In condition (1), adjust using screw (C) so that control lever (B)'s position is a [ie, the distance from idle switch (E) is L2], then fix using nut (D).
T:Tightening torque
b:Alpha
----------
L1=34.1+3.5-5.5mm L2=5.1+-0.5mm a=9deg P1=-66.6kPa P2=-500mmHg T=6~9N-m(0.6~0.9kgf-m)
----------
a=9deg b=12.5+-4deg L2=5.1+-0.5mm
----------
L1=34.1+3.5-5.5mm L2=5.1+-0.5mm a=9deg P1=-66.6kPa P2=-500mmHg T=6~9N-m(0.6~0.9kgf-m)
----------
a=9deg b=12.5+-4deg L2=5.1+-0.5mm
0000002001 DASHPOT ADJUSTMENT
Adjustment of the dash pot
1. Maintain the control lever (A) position at a (distance L from idle screw [D])
2. In this condition of item 1., adjust the position of dashpot (B) so that the end of dashpot (B) contacts the control lever (A). Then, fix using bolt (C).
Tightening torque is T.
D:Dash pot contact position
----------
L=8.1-0.3mm T=6~9N-m(0.6~0.9Kgf-m) a=14.1deg-0.5deg
----------
L=8.1-0.3mm a=14.1deg-0.5deg b=12.5deg+-4deg
----------
L=8.1-0.3mm T=6~9N-m(0.6~0.9Kgf-m) a=14.1deg-0.5deg
----------
L=8.1-0.3mm a=14.1deg-0.5deg b=12.5deg+-4deg