Rating:
Information injection-pump assembly
BOSCH
9 460 614 424
9460614424
ZEXEL
104741-4030
1047414030
Components :
0. | INJECTION-PUMP ASSEMBLY | 104741-4030 |
1. | _ | |
2. | FUEL INJECTION PUMP | |
3. | NUMBER PLATE | |
4. | _ | |
5. | CAPSULE | |
6. | ADJUSTING DEVICE | |
7. | NOZZLE AND HOLDER ASSY | |
8. | Nozzle and Holder | |
9. | Open Pre:MPa(Kqf/cm2) | |
10. | NOZZLE-HOLDER | |
11. | NOZZLE |
Include in #2:
104741-4030
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 460 614 424
9460614424
ZEXEL
104741-4030
1047414030
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
(Note)
For Japan: year/month/day (change sequence) 1988/12/7(2)
For Japan: year/month/day (change sequence) 1988/12/7(2)
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
54.9
54.4
55.4
Difference in delivery
mm3/st.
4.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2150
2150
2150
Average injection quantity
mm3/st.
18.1
14.6
21.6
Injection timing adjustment_03
Pump speed
r/min
1900
1900
1900
Average injection quantity
mm3/st.
50.95
48.5
53.4
Injection timing adjustment_04
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
54.9
53.9
55.9
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
51.55
49.5
53.6
Injection timing adjustment_06
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
54.6
54.1
55.1
Difference in delivery
mm3/st.
4.5
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_07
Pump speed
r/min
2150
2150
2150
Average injection quantity
mm3/st.
17.7
14.2
21.2
Remarks
For Japan
For Japan
Injection timing adjustment_08
Pump speed
r/min
1900
1900
1900
Average injection quantity
mm3/st.
52.1
49.7
54.5
Remarks
For Japan
For Japan
Injection timing adjustment_09
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
54.6
53.6
55.6
Remarks
For Japan
For Japan
Injection timing adjustment_10
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
51.4
49.4
53.4
Remarks
For Japan
For Japan
Injection quantity adjustment
Pump speed
r/min
2150
2150
2150
Average injection quantity
mm3/st.
18.1
15.1
21.1
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
3
Injection quantity adjustment_03
Pump speed
r/min
2150
2150
2150
Average injection quantity
mm3/st.
17.7
14.7
20.7
Basic
*
Remarks
For Japan
For Japan
Injection quantity adjustment_04
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
3
Remarks
For Japan
For Japan
Governor adjustment
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
10.25
8.2
12.3
Difference in delivery
mm3/st.
3
Basic
*
Governor adjustment_02
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
10.25
8.2
12.3
Governor adjustment_03
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
3
Governor adjustment_04
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
10
8
12
Difference in delivery
mm3/st.
3
Basic
*
Remarks
For Japan
For Japan
Governor adjustment_05
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
10
8
12
Remarks
For Japan
For Japan
Governor adjustment_06
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
3
Remarks
For Japan
For Japan
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
56
56
Basic
*
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
55
55
Basic
*
Remarks
For Japan
For Japan
Speed control lever angle
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
Speed control lever angle_02
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan: Magnet OFF
For Japan: Magnet OFF
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
363
240
486
_02
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
381
252
510
Remarks
For Japan
For Japan
Stop lever angle
Pump speed
r/min
1000
1000
1000
Pressure
kPa
451.5
422
481
Pressure
kgf/cm2
4.6
4.3
4.9
Basic
*
Stop lever angle_02
Pump speed
r/min
500
500
500
Pressure
kPa
294.5
265
324
Pressure
kgf/cm2
3
2.7
3.3
Stop lever angle_03
Pump speed
r/min
1000
1000
1000
Pressure
kPa
451.5
422
481
Pressure
kgf/cm2
4.6
4.3
4.9
Stop lever angle_04
Pump speed
r/min
1800
1800
1800
Pressure
kPa
686.5
657
716
Pressure
kgf/cm2
7
6.7
7.3
Stop lever angle_05
Pump speed
r/min
1000
1000
1000
Pressure
kPa
441.5
412
471
Pressure
kgf/cm2
4.5
4.2
4.8
Basic
*
Remarks
For Japan
For Japan
Stop lever angle_06
Pump speed
r/min
500
500
500
Pressure
kPa
284.5
255
314
Pressure
kgf/cm2
2.9
2.6
3.2
Remarks
For Japan
For Japan
Stop lever angle_07
Pump speed
r/min
1000
1000
1000
Pressure
kPa
441.5
412
471
Pressure
kgf/cm2
4.5
4.2
4.8
Remarks
For Japan
For Japan
Stop lever angle_08
Pump speed
r/min
1800
1800
1800
Pressure
kPa
676.5
647
706
Pressure
kgf/cm2
6.9
6.6
7.2
Remarks
For Japan
For Japan
0000001101
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.4
1.2
1.6
Basic
*
_02
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.4
1.1
1.7
_03
Pump speed
r/min
1400
1400
1400
Timer stroke
mm
3.4
2.8
4
_04
Pump speed
r/min
1800
1800
1800
Timer stroke
mm
5
4.5
5.5
_05
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.4
1.2
1.6
Basic
*
Remarks
For Japan
For Japan
_06
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.4
1.1
1.7
Remarks
For Japan
For Japan
_07
Pump speed
r/min
1400
1400
1400
Timer stroke
mm
3.3
2.7
3.9
Remarks
For Japan
For Japan
_08
Pump speed
r/min
1800
1800
1800
Timer stroke
mm
4.9
4.4
5.4
Remarks
For Japan
For Japan
0000001201
Max. applied voltage
V
16
16
16
Test voltage
V
25
24
26
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.1
1
1.2
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
36
31
41