Rating:
Information injection-pump assembly
ZEXEL
101901-0970
1019010970
ISUZU
1156008650
1156008650
Cross reference number
ZEXEL
101901-0970
1019010970
ISUZU
1156008650
1156008650
Zexel num
Bosch num
Firm num
Name
101901-0970
1156008650 ISUZU
INJECTION-PUMP ASSEMBLY
10PA1 * K
10PA1 * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
134424-0020
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
R: right hand row, L: left hand row 1L-8R-7L -3L-6R-5 L-4R-2R
R: right hand row, L: left hand row 1L-8R-7L -3L-6R-5 L-4R-2R
Pre-stroke
mm
3.4
3.35
3.45
Beginning of injection position
Opposite to the driving side NO.1
Opposite to the driving side NO.1
Difference between angles 1
Cal 1-8 deg. 45 44.5 45.5
Cal 1-8 deg. 45 44.5 45.5
Difference between angles 2
Cal 1-7 deg. 90 89.5 90.5
Cal 1-7 deg. 90 89.5 90.5
Difference between angles 3
Cal 1-3 deg. 135 134.5 135.5
Cal 1-3 deg. 135 134.5 135.5
Difference between angles 4
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 5
Cal 1-5 deg. 225 224.5 225.5
Cal 1-5 deg. 225 224.5 225.5
Difference between angles 6
Cal 1-4 deg. 270 269.5 270.5
Cal 1-4 deg. 270 269.5 270.5
Difference between angles 7
Cyl.1-2 deg. 315 314.5 315.5
Cyl.1-2 deg. 315 314.5 315.5
Injection quantity adjustment
Adjusting point
A
Rack position
11.3
Pump speed
r/min
1300
1300
1300
Average injection quantity
mm3/st.
86
84
88
Max. variation between cylinders
%
0
-4
4
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
11.3
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
77
76
78
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
11.7+-0.
5
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
72
69
75
Max. variation between cylinders
%
0
-4
4
Fixing the lever
*
Remarks
After startup boost setting
After startup boost setting
Injection quantity adjustment_04
Adjusting point
D
Rack position
8.2+-0.5
Pump speed
r/min
225
225
225
Average injection quantity
mm3/st.
8
6.7
9.3
Max. variation between cylinders
%
0
-13
13
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Injection quantity adjustment_05
Adjusting point
E
Rack position
14.7+-0.
5
Pump speed
r/min
150
150
150
Each cylinder's injection qty
mm3/st.
95
95
Fixing the lever
*
Remarks
After startup boost setting
After startup boost setting
Timer adjustment
Pump speed
r/min
1050
Advance angle
deg.
0.3
Timer adjustment_02
Pump speed
r/min
1100
Advance angle
deg.
1.1
0.1
1.1
Timer adjustment_03
Pump speed
r/min
1250
Advance angle
deg.
2.8
2.3
3.3
Timer adjustment_04
Pump speed
r/min
1350
Advance angle
deg.
4.6
4.1
5.1
Timer adjustment_05
Pump speed
r/min
-
Advance angle
deg.
5.5
5.5
5.5
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Beginning of damper spring operation: DL
(2)Rack limit (operating at delivery)
(3)Set the load lever's stop position so that R = aa (N = 0).
(4)Excess fuel setting for starting: SXL
----------
DL=6-0.5mm aa=7.5mm SXL=12+0.2mm
----------
----------
DL=6-0.5mm aa=7.5mm SXL=12+0.2mm
----------
Speed control lever angle
F:Full speed
M:Minimum-maximum speed
(1)Pump speed = aa
----------
aa=500r/min
----------
a=12deg+-5deg b=5.5deg+-5deg
----------
aa=500r/min
----------
a=12deg+-5deg b=5.5deg+-5deg
0000000901
F:Full load
I:Idle
S:Stop
(1)Rack position aa (pump speed bb r/min )
----------
aa=7.5mm bb=0r/min
----------
a=30.5deg+-3deg b=13deg+-5deg c=1.5deg+-5deg
----------
aa=7.5mm bb=0r/min
----------
a=30.5deg+-3deg b=13deg+-5deg c=1.5deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=40deg+-5deg b=71deg+-5deg
----------
----------
a=40deg+-5deg b=71deg+-5deg
Have questions with 101901-0970?
Group cross 101901-0970 ZEXEL
Isuzu
101901-0970
1156008650
INJECTION-PUMP ASSEMBLY
10PA1
10PA1