101606-1790 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016061790


101606-1790 INJECTION-PUMP ASSEMBLY
Rating:
77
Buy INJECTION-PUMP ASSEMBLY 101606-1790 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101606-1790 1016061790

Cross reference number

ZEXEL 101606-1790 1016061790


Zexel num
Bosch num
Firm num
Name
101606-1790 
101606-1792 
 
  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D31T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-6220
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.6
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   48.8 47.2 50.4
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   10.3+-0. 5
Pump speed r/min   275 275 275
Average injection quantity mm3/st.   8 6.7 9.3
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.6)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   48.8 47.8 49.8
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.55
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   64.9 60.9 68.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   (R1-0.05 )
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   32.9 28.9 36.9
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60.5 60.5 65.5
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1500--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1450
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   3.5 3 4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101606-1790
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=D19
----------

Speed control lever angle

Test data 101606-1790
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=40mm
----------
a=26deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101606-1790
N:Engine manufacturer's normal use S:Stop the pump. (1)Free (at shipping) (2)Use the hole at R = aa (3)Rack position corresponding to bb (4)Set the stopper bolt so that speed = cc and rack position = dd. Confirm non-injection. (5)After setting the stopper bolt, confirm non-injection at speed ee. (rack position = ff)
----------
aa=40mm bb=16mm cc=1700r/min dd=6.5-0.5mm ee=275r/min ff=8mm
----------
a=8deg+-5deg b=15deg+-5deg c=25deg+-5deg

Timing setting

Test data 101606-1790
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=9deg
----------
a=(1deg)




Have questions with 101606-1790?





Group cross 101606-1790 ZEXEL

Mitsubishi 

F 019 Z20 474 
ME076242 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 464 
ME076246 
INJECTION-PUMP ASSEMBLY
6D16T
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME076209 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D16T
 
ME076211 
INJECTION-PUMP ASSEMBLY
6D16T
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035492 
INJECTION-PUMP ASSEMBLY
6D15
9 400 615 465 
ME056729 
INJECTION-PUMP ASSEMBLY
6D22
9 400 615 466 
ME047505 
INJECTION-PUMP ASSEMBLY
6D16T
9 400 619 989 
ME076257 
INJECTION-PUMP ASSEMBLY
6D16
101606-1790  

101606-1792 
 
 
INJECTION-PUMP ASSEMBLY
6D31T
9 400 615 467 
ME086566 
INJECTION-PUMP ASSEMBLY
6D31T