Rating:
Information injection-pump assembly
ZEXEL
101601-5371
1016015371
Service parts 101601-5371 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
23600-1843
12.
Open Pre:MPa(Kqf/cm2)
14.7{150}/19.6{200}
15.
NOZZLE SET
Cross reference number
ZEXEL
101601-5371
1016015371
Zexel num
Bosch num
Firm num
Name
101601-5371
INJECTION-PUMP ASSEMBLY
14BE PE6A PE
14BE PE6A PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-5720
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3.1
3.07
3.13
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.75 60.25
Cal 1-4 deg. 60 59.75 60.25
Difference between angles 2
Cyl.1-2 deg. 120 119.75 120.25
Cyl.1-2 deg. 120 119.75 120.25
Difference between angles 3
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 4
Cal 1-3 deg. 240 239.75 240.25
Cal 1-3 deg. 240 239.75 240.25
Difference between angles 5
Cal 1-5 deg. 300 299.75 300.25
Cal 1-5 deg. 300 299.75 300.25
Injection quantity adjustment
Adjusting point
-
Rack position
9.6
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
57.9
55.9
59.9
Max. variation between cylinders
%
0
-3.5
3.5
Basic
*
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_02
Adjusting point
H
Rack position
7.8+-0.5
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
5.3
3.8
6.8
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_03
Adjusting point
A
Rack position
R1(9.6)
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
57.9
56.9
58.9
Basic
*
Fixing the lever
*
Injection quantity adjustment_04
Adjusting point
B
Rack position
R1(9.6)
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
63.9
59.9
67.9
Fixing the lever
*
Injection quantity adjustment_05
Adjusting point
C
Rack position
R1-0.25
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
40.3
36.3
44.3
Fixing the lever
*
Injection quantity adjustment_06
Adjusting point
D
Rack position
R1(9.6)
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
63.7
59.7
67.7
Fixing the lever
*
Injection quantity adjustment_07
Adjusting point
E
Rack position
R1+0.45
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
39.9
35.9
43.9
Fixing the lever
*
Injection quantity adjustment_08
Adjusting point
I
Rack position
14.5+-0.
5
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
108
108
118
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
1330--
Advance angle
deg.
0
0
0
Load
3/4
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
1280
Advance angle
deg.
0.3
Load
3/4
Timer adjustment_03
Pump speed
r/min
1500
Advance angle
deg.
4.5
4.2
4.8
Load
4/4
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Torque cam stamping: T1
(2)RACK LIMIT
----------
T1=C02
----------
----------
T1=C02
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Stopper bolt set position 'H'
----------
----------
a=37deg+-5deg b=(40deg)+-3deg
----------
----------
a=37deg+-5deg b=(40deg)+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=40deg+-5deg b=40deg+-5deg
----------
----------
a=40deg+-5deg b=40deg+-5deg
0000001501 LEVER
(E): fix
1. Air cylinder adjustment
(1)With the speed lever in the idling position, temporarily set the clearance between speed lever (A) and set bolt (B) at approximately L.
(2)Set pump speed to N1 and apply pressure P1 to the air cylinder (C).
(3)Gradually push out set bolt (B) so that the rack position is R1 at pump speed N2. Then tighten nut (D).
(4)Apply air pressure several times.
(5)Confirm that the lever returns to the idling position at pressure P2.
(6)Also, confirm that the rack position is R1 at air pressure P = P1.
----------
L=(1.4)mm N1=475r/min P1=392+98kpa(4+1kgf/cm2) N2=475r/min R1=7.3+-0.1mm P2=0kpa(0kgf/cm2)
----------
----------
L=(1.4)mm N1=475r/min P1=392+98kpa(4+1kgf/cm2) N2=475r/min R1=7.3+-0.1mm P2=0kpa(0kgf/cm2)
----------
Timing setting
(1)Pump vertical direction
(2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(70deg)
----------
----------
a=(70deg)
Have questions with 101601-5371?
Group cross 101601-5371 ZEXEL
Hino
Hino
Hino
Hino
101601-5371
INJECTION-PUMP ASSEMBLY