Rating:
Information injection-pump assembly
BOSCH
F 01G 09U 1JJ
f01g09u1jj
ZEXEL
101481-9380
1014819380
NISSAN-DIESEL
16712NA00D
16712na00d
Service parts 101481-9380 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
15.7(160)
15.
NOZZLE SET
Cross reference number
BOSCH
F 01G 09U 1JJ
f01g09u1jj
ZEXEL
101481-9380
1014819380
NISSAN-DIESEL
16712NA00D
16712na00d
Zexel num
Bosch num
Firm num
Name
101481-9380
F 01G 09U 1JJ
16712NA00D NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
BD30 K
BD30 K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-1520
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
3.2
3.15
3.25
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
10.2
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
53
52
54
Max. variation between cylinders
%
0
-3.5
3.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
9.1+-0.5
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
8
6
10
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Injection quantity adjustment_03
Adjusting point
C
Rack position
11.6++
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
60
60
70
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
(N1+50)-
-
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
(850)
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1500
Advance angle
deg.
2.6
2.1
3.1
Timer adjustment_04
Pump speed
r/min
(1650)
Advance angle
deg.
4.2
3.7
4.7
Remarks
Finish
Finish
Timer adjustment_05
Pump speed
r/min
1800
Advance angle
deg.
4.2
3.7
4.7
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT
(4)Set idle sub-spring
(5)Main spring setting
(6)Rack difference between N = N1 and N = N2
----------
K=13 N1=1500r/min N2=400r/min
----------
----------
K=13 N1=1500r/min N2=400r/min
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Set the pump speed at aa. ( At delivery )
(2)When pump speed set at bb
(3)Stopper bolt setting
(4)Stopper bolt setting
----------
aa=1825r/min bb=1515r/min
----------
a=31deg+-5deg b=19deg+-5deg c=9deg+-5deg
----------
aa=1825r/min bb=1515r/min
----------
a=31deg+-5deg b=19deg+-5deg c=9deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Normal
----------
----------
a=12deg+-5deg b=53deg+-5deg
----------
----------
a=12deg+-5deg b=53deg+-5deg
0000001501 GOV FULL LOAD ADJUSTMENT
Title1:Full load stopper adjustment
Title2:Governor set speed
LABEL1:Distinguishing
LABEL2:Pump speed (r/min)
LABEL3:Ave. injection quantity (mm3/st)
LABEL4:Max. var. bet. cyl.
LABEL5:Remarks
LABEL6:Distinguishing
LABEL7:Governor set speed (r/min)
LABEL8:Remarks
(1)Adjustment conditions are the same as those for measuring injection quantity.
(2)-
----------
----------
a1=A a2=- r1=1500r/min r2=- Q1=53+-1mm3/st Q2=- c1=+-3.5% c2=- a3=36 a4=30 r3=1800r/min r4=1500r/min
----------
----------
a1=A a2=- r1=1500r/min r2=- Q1=53+-1mm3/st Q2=- c1=+-3.5% c2=- a3=36 a4=30 r3=1800r/min r4=1500r/min
Timing setting
(1)Pump vertical direction
(2)Position of gear mark 'ZZ' at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(100deg)
----------
----------
a=(100deg)
Have questions with 101481-9380?
Group cross 101481-9380 ZEXEL
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
101481-9380
F 01G 09U 1JJ
16712NA00D
INJECTION-PUMP ASSEMBLY
BD30
BD30