101603-4440 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016034440 1156018902


101603-4440 INJECTION-PUMP ASSEMBLY
Rating:
29
Buy INJECTION-PUMP ASSEMBLY 101603-4440 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-4440 1016034440
ISUZU 1156018902 1156018902

Cross reference number

ZEXEL 101603-4440 1016034440
ISUZU 1156018902 1156018902


Zexel num
Bosch num
Firm num
Name
101603-4440 
101603-4441 
 
1156018902  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.6
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   60 58.4 61.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   9.2 7.9 10.5
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.6)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   60 59 61
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.4
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   52.5 49.3 55.7
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.05
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   42.3 39.1 45.5
Fixing the lever   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1300
Advance angle deg.   1.8 1.3 2.3
Timer adjustment_04
Pump speed r/min   1600
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-4440
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT: RAL
----------
T1=A86 RAL=17.3+0.2mm
----------

Speed control lever angle

Test data 101603-4440
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=43deg+-5deg b=(45deg)+-3deg

Stop lever angle

Test data 101603-4440
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101603-4440
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=1000r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(11.6)mm Rb=R1-0.7mm Pa=89.8+-2.7kPa(674+-20mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=60+-1cm3/1000st Q2=-

Timing setting

Test data 101603-4440
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(60deg)




Have questions with 101603-4440?





Group cross 101603-4440 ZEXEL

Isuzu 

 
1156022362 
INJECTION-PUMP ASSEMBLY
6BD1-T
9 400 610 649 
1156022364 
INJECTION-PUMP ASSEMBLY
6BD1-T
9 400 619 798 
1156022382 
INJECTION-PUMP ASSEMBLY
6BD1T
9 400 610 650 
1156022384 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156018882 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156018892 
INJECTION-PUMP ASSEMBLY
6BD1
101603-4440  

101603-4441 
 
1156018902 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 615 082 
1156018904 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156018910 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 619 551 
1156022212 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 615 083 
1156022214 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156021962 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 615 084 
1156021964 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156022660 
INJECTION-PUMP ASSEMBLY
6BG1TC
 
1156022670 
INJECTION-PUMP ASSEMBLY
6BG1TC
 
1156022671 
INJECTION-PUMP ASSEMBLY
6BG1TC
 
1156022672 
INJECTION-PUMP ASSEMBLY
6BG1TC
9 400 615 085 
1156022673 
INJECTION-PUMP ASSEMBLY
6BG1-TC