101603-0780 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016030780 1156018580


101603-0780 INJECTION-PUMP ASSEMBLY
Rating:
41
Buy INJECTION-PUMP ASSEMBLY 101603-0780 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-0780 1016030780
ISUZU 1156018580 1156018580

Service parts 101603-0780 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-2830
3. GOVERNOR 105931-3460
4. SUPPLY PUMP 105220-5220
5. AUTOM. ADVANCE MECHANIS 105644-0170
6. COUPLING PLATE 105661-0421
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4823
11. Nozzle and Holder 1-15300-104-2
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105030-3201
14. NOZZLE 105015-4130
15. NOZZLE SET

Include in #1:

101603-0780 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101603-0780 1016030780
ISUZU 1156018580 1156018580


Zexel num
Bosch num
Firm num
Name
101603-0780 
101603-0783 
 
1156018580  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.5
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   76.5 74.9 78.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   260 260 260
Average injection quantity mm3/st.   8.1 6.8 9.4
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.5)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   76.5 75.5 77.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   I
Rack position   15.3+-0. 5
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   92 92 100
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1350--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1300
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1400
Advance angle deg.   2 1.5 2.5
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   4.5 4 5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-0780
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=B25
----------

Speed control lever angle

Test data 101603-0780
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=(43deg)+-3deg b=42deg+-5deg

Stop lever angle

Test data 101603-0780
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

Timing setting

Test data 101603-0780
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(60deg)




Have questions with 101603-0780?





Group cross 101603-0780 ZEXEL

Isuzu 

 
1156016181 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016191 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018601 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018611 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018621 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018540 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156018550 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156018551 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156018570 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018571 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018572 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018573 
INJECTION-PUMP ASSEMBLY
6BG1
101603-0780  

101603-0783 
 
1156018580 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018581 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018582 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018583 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018590 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018591 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018592 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018593 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018594 
INJECTION-PUMP ASSEMBLY
6BG1
Back to top