106671-8780 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066718780 220801681a


106671-8780 INJECTION-PUMP ASSEMBLY
Rating:
29
Buy INJECTION-PUMP ASSEMBLY 106671-8780 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106671-8780 1066718780
HINO 220801681A 220801681a

Service parts 106671-8780 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-7441
3. GOVERNOR 105489-5240
4. SUPPLY PUMP 105217-1910
5. AUTOM. ADVANCE MECHANIS 105681-5370
6. COUPLING PLATE 105663-0620
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-7403
11. Nozzle and Holder 23600-2470C
12. Open Pre:MPa(Kqf/cm2) 14.7{150}/21.6{220}
13. NOZZLE-HOLDER 105031-7241
14. NOZZLE
15. NOZZLE SET 105019-0150

Include in #1:

106671-8780 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106671-8780 1066718780
HINO 220801681A 220801681a


Zexel num
Bosch num
Firm num
Name
106671-8780 
106671-8781 
 
220801681A  HINO
INJECTION-PUMP ASSEMBLY
K13D * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1420
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-4-2-6- 3-5
Pre-stroke mm   4.6 4.54 4.6
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   7.1
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   140 137 143
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   7.4
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   147.5 145.5 149.5
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   7.6
Pump speed r/min   1075 1075 1075
Average injection quantity mm3/st.   155 152 158
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   D
Rack position   3.7+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   8.8 5.8 11.8
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Injection quantity adjustment_05
Adjusting point   F
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   155 155 175
Fixing the lever   *
Remarks
After startup boost setting
 
Injection quantity adjustment_06
Adjusting point   H
Rack position   7.6+-0.5
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   153 147 159
Fixing the lever   *
Timer adjustment
Pump speed r/min   900--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   850
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1075-50
Advance angle deg.   4.5 4.2 4.8
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106671-8780
N:Pump speed R:Rack position (mm) (1)Lever ratio: RT (2)Target shim dimension: TH (3)Tolerance for racks not indicated: +-0.05mm. (4)Excess fuel setting for starting: SXL (N = N1) (5)Damper spring setting (6)Variable speed specification: idling adjustment (7)Main spring setting
----------
RT=0.8 TH=2.9mm SXL=8.1+-0.1mm N1=350r/min
----------

Speed control lever angle

Test data 106671-8780
F:Full speed I:Idle (1)Use the hole at R = aa (2)Set the pump speed at bb. (3)Stopper bolt setting (4)Set the speed at cc, set the stopper bolt.
----------
aa=130mm bb=1150r/min cc=350r/min
----------
a=15deg+-5deg b=(12deg)+-5deg

0000000901

Test data 106671-8780
F:Full load I:Idle (1)Stopper bolt setting (2)Use the hole at R = aa
----------
aa=45mm
----------
a=24deg+-5deg b=36deg+-3deg

Stop lever angle

Test data 106671-8780
N:Pump normal S:Stop the pump. (1)Set stopper screw so that rack position = aa (after setting, apply red paint). (2)Use the hole at R = bb (3)Drive side
----------
aa=(13)+-1mm bb=36mm
----------
a=47deg+-5deg b=33.5deg+-5deg

0000001201

Test data 106671-8780
(1)Variable speed specification (2)Minimum - maximum speed specification (3)Use the hole at R = aa
----------
aa=112mm
----------
a=20deg+-5deg b=(29deg)

0000001501 RACK SENSOR

Test data 106671-8780
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (-0620) (1)Fix the speed control lever at the full position (2)Set the speed to N1 r/min. (If the boost compensator is provided, apply boost pressure.) (3)Adjust the bobbin (A) so that the rack sensor's output voltage is VR+-0.01. (4)At that time, rack position must be Ra. (5)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
N1=900r/min Ra=(7.6)mm
----------

0000001601 GOVERNOR TORQUE CONTROL

Test data 106671-8780
Dr:Torque control stroke (A): Without torque control spring capsule 1. Adjustment procedures (1)Procedure is the same as that for the RFD (former type), except that the positive torque control stroke must be determined at the full lever setting. 2. Procedures for adjustment (1)Remove the torque control spring capsule. (2)Operate the pump at approximately N1. (End of idling spring operation < N1.) (3)Tilt the lever to the full side. (4)Set so that R = RF. (5)Increase the speed by pushing in the screw (attached to the bracket on the rear of the tension lever) through the adjusting window. (6)Adjust so that the torque control stroke Dr1 can be obtained. (7)Align N2 and N3 with the torque control spring capsule. 3. Final confirmation (1)After final confirmation, temporarily set the load lever to N = N1, R = idling position. (2)From this condition, increase speed to N = N4. (3)Confirm that positive torque control stroke is Dr2.
----------
N1=500r/min N2=(565)r/min N3=(700)r/min N4=850r/min RF=7.1mm Dr1=0.5mm Dr2=0+0.3mm
----------

0000001701 LEVER

Test data 106671-8780
2-stage changeover lever adjustment (A) Speed lever (B) Load lever (C) 2-stage changeover lever (D) Link (E) Bolt (G) Variable speed specifications (H) Minimum maximum speed specifications F:Full speed I:Idle 1. Minimum-maximum speed specification adjustment (when running) (1)After completing governor adjustment, hold the 2-stage changeover lever (C) so that the speed lever (A) contacts the full speed stopper. (2)In this condition, the load lever is held in the idle position. (3)Adjust bolt (E) so that the clearance between the pin underneath lever (C) and the end of the long groove in link (D) is L. (4)Lock using the nut. 2. Variable speed specification adjustment (at operation) (1)Hold the 2-stage changeover lever (C) so that the load lever (B) contacts the full load stopper. (When the load lever is equipped with a cancel mechanism, move it so that it contacts the stopper without canceling.) (2)In this condition, confirm that the speed lever (A) moves from idle to full speed.
----------
L=1~2mm
----------

Timing setting

Test data 106671-8780
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(3deg)




Have questions with 106671-8780?





Group cross 106671-8780 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
S220204320A 
INJECTION-PUMP ASSEMBLY
9 400 610 888 
220204320A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
220008330A 
INJECTION-PUMP ASSEMBLY
K-4
9 400 619 768 
220008330B 
INJECTION-PUMP ASSEMBLY
K-4
9 400 610 889 
220008331A 
INJECTION-PUMP ASSEMBLY
K-4
9 400 617 015 
220008331B 
INJECTION-PUMP ASSEMBLY
K-4
 
220008560A 
INJECTION-PUMP ASSEMBLY
K13U
 
220008561A 
INJECTION-PUMP ASSEMBLY
K13U
9 400 617 016 
220008562A 
INJECTION-PUMP ASSEMBLY
K13U
 
220801650A 
INJECTION-PUMP ASSEMBLY
K-4
 
220801650B 
INJECTION-PUMP ASSEMBLY
K-4
9 400 617 017 
220801651A 
INJECTION-PUMP ASSEMBLY
K-4
F 019 Z10 415 
220204470A 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 019 Z10 416 
220204471A 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 019 Z10 417 
220204472A 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 01G 09U 07X 
220204472B 
INJECTION-PUMP ASSEMBLY
P09B-TB
F 019 Z10 243 
220204473A 
INJECTION-PUMP ASSEMBLY
P09B-TB
9 400 610 890 
220204474A 
INJECTION-PUMP ASSEMBLY
P09B-TB
 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 617 018 
220008830A 
INJECTION-PUMP ASSEMBLY
K13D
 
220008910A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 610 891 
220008911A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 611 901 
220008911B 
INJECTION-PUMP ASSEMBLY
K13D
 
220204560A 
INJECTION-PUMP ASSEMBLY
K13C-T
9 400 610 892 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 610 892 
S220204561A 
INJECTION-PUMP ASSEMBLY
9 400 612 077 
220204561A 
INJECTION-PUMP ASSEMBLY
K13C-T
106671-8780  

106671-8781 
 
220801681A 
INJECTION-PUMP ASSEMBLY
K13D
 
220801682A 
INJECTION-PUMP ASSEMBLY
K13D
9 400 617 019 
220801682B 
INJECTION-PUMP ASSEMBLY
K13D
 
220204640A 
INJECTION-PUMP ASSEMBLY
K13C-T
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
9 400 610 893 
 
INJECTION-PUMP ASSEMBLY
K13C-T

Hino 

9 400 613 232 
220204641A 
INJECTION-PUMP ASSEMBLY
K13C-T
Back to top