106671-6520 ZEXEL 9 400 612 273 BOSCH INJECTION-PUMP ASSEMBLY 9400612273 1066716520


106671-6520 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 106671-6520 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 612 273 9400612273
ZEXEL 106671-6520 1066716520

Service parts 106671-6520 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-6470
3. GOVERNOR 105960-0360
4. SUPPLY PUMP 105237-4420
5. AUTOM. ADVANCE MECHANIS 105681-6030
6. COUPLING PLATE 105664-2011
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-8112
11. Nozzle and Holder 1-15300-389-1
12. Open Pre:MPa(Kqf/cm2) 18.1{185}/22.1{225}
13. NOZZLE-HOLDER 105041-2082
14. NOZZLE
15. NOZZLE SET 105019-2660

Include in #1:

106671-6520 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 273 9400612273
ZEXEL 106671-6520 1066716520


Zexel num
Bosch num
Firm num
Name
106671-6520 
106671-6521 
9 400 612 273 
   
INJECTION-PUMP ASSEMBLY
* K 14CA PE6P,6PD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-4320
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED4 control unit part number   407915-0 590
RED4 rack sensor specifications mm   19
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   2.9 2.87 2.93
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Rack position   (11.8)
PWM %   54.8
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   130.5 129.5 131.5
Max. variation between cylinders %   0 -3 3
Basic   *
Injection quantity adjustment_02
Rack position   (7.4)
PWM %   29.9+-2. 8
Pump speed r/min   450 450 450
Average injection quantity mm3/st.   10.5 8.5 12.5
Max. variation between cylinders %   0 -15 15
Governor adjustment
Pump speed r/min   1200++
Advance angle deg.   0 0 0
Remarks
Do not advance until starting N = 1200.
 
Governor adjustment_02
Pump speed r/min   -
Advance angle deg.   0.7 0.7 0.7
Remarks
Measure the actual speed, stop
 

Test data Ex:

Speed control lever angle

Test data 106671-6520
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg

0000000901

Test data 106671-6520
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=9deg
----------
a=(50deg)

Stop lever angle

Test data 106671-6520
(PWM) Pulse width modulation (%) (R) Rack position (mm) Rack sensor output characteristics 1. Rack limit adjustment (1)Measure the rack position R2 for PWM a2%. (2)Confirm that it is within the range R2 = 15+-1 mm. (3)Measure the rack position R1 at PWM a %. (4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm. 2. Check the limp home operation. (1)Move the switch box's limp home switch to the limp home side. (2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table. 3. Check the pull down operation. (1)Confirm that the rack position is 19 mm at PWM B%. (2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5 % B=95%
----------




Have questions with 106671-6520?





Group cross 106671-6520 ZEXEL

Isuzu 

9 400 612 040 
1156033890 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 612 041 
1156033940 
INJECTION-PUMP ASSEMBLY
6HK1-T
106671-6520  

106671-6521 
9 400 612 273 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 616 911 
1156033570 
INJECTION-PUMP ASSEMBLY
6HK1-XQB
9 400 616 912 
1156033590 
INJECTION-PUMP ASSEMBLY
6SD1-TCE
9 400 616 913 
1156034080 
INJECTION-PUMP ASSEMBLY
6SD1-TCE
9 400 612 222 
1156034170 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 612 307 
1156034171 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 613 010 
1156034172 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 612 223 
1156034180 
INJECTION-PUMP ASSEMBLY
6HK1-T
 
1156034260 
INJECTION-PUMP ASSEMBLY
6WG1-T
9 400 612 426 
1156034261 
INJECTION-PUMP ASSEMBLY
6WG1-T
9 400 612 274 
1156034290 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 616 914 
1156034291 
INJECTION-PUMP ASSEMBLY
6HK1-T
9 400 612 464 
1156034300 
INJECTION-PUMP ASSEMBLY
6HE1-TMC
Back to top