106671-2770 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066712770 me056376


106671-2770 INJECTION-PUMP ASSEMBLY
Rating:
11
Buy INJECTION-PUMP ASSEMBLY 106671-2770 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106671-2770 1066712770
MITSUBISHI ME056376 me056376

Cross reference number

ZEXEL 106671-2770 1066712770
MITSUBISHI ME056376 me056376


Zexel num
Bosch num
Firm num
Name
106671-2770 
 
ME056376  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D23 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   7.6
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   97 94.2 99.8
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   F
Rack position   5+-0.5
Pump speed r/min   500 500 500
Each cylinder's injection qty mm3/st.   16.5 14 19
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(7.6)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   97 96 98
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(7.6)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   111 107 115
Difference in delivery mm3/st.   8 8 8
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   5.7+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   16.5 13.7 19.3
Fixing the rack   *
Remarks
(check)
 
Injection quantity adjustment_06
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   115 95 135
Fixing the lever   *
Timer adjustment
Pump speed r/min   950
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   1050
Advance angle deg.   2.2 1.7 2.7
Timer adjustment_03
Pump speed r/min   1150
Advance angle deg.   5.5 5 6
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106671-2770
N:Pump speed R:Rack position (mm) (1)Beginning of damper spring operation: DL (2)Excess fuel setting for starting: SXL
----------
DL=4.5-0.2mm SXL=R1(7.6)+0.2mm
----------

Speed control lever angle

Test data 106671-2770
F:Full speed
----------

----------
a=28deg+-5deg

0000000901

Test data 106671-2770
F:Full load I:Idle (1)At idle increase (2)Stopper bolt setting
----------

----------
a=29deg+-5deg b=23deg+-3deg c=5deg

Stop lever angle

Test data 106671-2770
N:Pump normal S:Stop the pump.
----------

----------
a=6deg+-5deg b=64deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325+-0.5r/min Ra=5.4mm
----------

0000001601 LEVER

Test data 106671-2770
1. Idle increase mechanism adjustment procedure (1)Set lever (a) in the idle position. (2)Move the lever (A) a from the idle set position to the full side. (Temporarily fixed for adjustment.) (3)Adjust using screw (c) so that lever (B) contacts lever (A). (4)Turn screw (c) and fix it using the nut where the hole above aa moves from horizontal to position b.
----------
a=5deg b=25+-5deg c=50mm
----------




Have questions with 106671-2770?





Group cross 106671-2770 ZEXEL

Mitsubishi 

 
ME056325 
INJECTION-PUMP ASSEMBLY
6D22
 
ME059586 
INJECTION-PUMP ASSEMBLY
6D22CT
 
ME059580 
INJECTION-PUMP ASSEMBLY
6D22PT
9 400 616 758 
ME059587 
INJECTION-PUMP ASSEMBLY
6D22CT

Mitsubishi-Heav 

 
3256510180 
INJECTION-PUMP ASSEMBLY
S6A
 
3256520180 
INJECTION-PUMP ASSEMBLY
S6A
 
 
INJECTION-PUMP ASSEMBLY
S6A
9 400 613 335 
3256520181 
INJECTION-PUMP ASSEMBLY
S6A

Mitsubishi 

 
ME059598 
INJECTION-PUMP ASSEMBLY
6D22WT
 
ME056375 
INJECTION-PUMP ASSEMBLY
6D23
106671-2770  
 
ME056376 
INJECTION-PUMP ASSEMBLY
6D23
 
 
INJECTION-PUMP ASSEMBLY
6D22T4
 
ME056405 
INJECTION-PUMP ASSEMBLY
6D22T4
Back to top