104780-9171 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047809171 167006t079


104780-9171 INJECTION-PUMP ASSEMBLY
Rating:
17
Buy INJECTION-PUMP ASSEMBLY 104780-9171 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104780-9171 1047809171
NISSAN 167006T079 167006t079

Cross reference number

ZEXEL 104780-9171 1047809171
NISSAN 167006T079 167006t079


Zexel num
Bosch num
Firm num
Name
104780-9171 
104780-9172 
 
167006T079  NISSAN
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
(Solenoid timer adjustment condition)   OFF
Injection timing adjustment
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   44 43.5 44.5
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   40.8 38.3 43.3
Oil temperature degC   48 46 50
Injection timing adjustment_03
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   44 43 45
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   45.1 42.1 48.1
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   10.9 8.9 12.9
Basic   *
Oil temperature degC   55 52 58
Injection quantity adjustment_02
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   39.7 39.7 39.7
Oil temperature degC   52 50 54
Injection quantity adjustment_04
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   10.9 8.4 13.4
Basic   *
Oil temperature degC   55 52 58
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   7.7 5.7 9.7
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   7.7 5.2 10.2
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 45 80
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 45 80
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1100 1100 1100
Overflow quantity cm3/min   450 320 580
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1300 1300 1300
Pressure with S/T ON kPa   549 510 588
Pressure with S/T ON kgf/cm2   5.6 5.2 6
Pressure with S/T OFF kPa   471 442 500
Pressure with S/T OFF kgf/cm2   4.8 4.5 5.1
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
Stop lever angle_02
Pump speed r/min   1300 1300 1300
Pressure with S/T OFF kPa   471 432 510
Pressure with S/T OFF kgf/cm2   4.8 4.4 5.2
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
Stop lever angle_03
Pump speed r/min   2150 2150 2150
Pressure with S/T OFF kPa   647 608 686
Pressure with S/T OFF kgf/cm2   6.6 6.2 7
Oil temperature degC   52 50 54
0000001101
Pump speed r/min   1300 1300 1300
Timer stroke with S/T ON mm   4.4 4 4.8
Timer stroke with S/T OFF mm   2.9 2.7 3.1
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_02
Pump speed r/min   1100 1100 1100
Timer stroke with S/T OFF mm   1.9 1.4 2.4
Oil temperature degC   50 48 52
_03
Pump speed r/min   1300 1300 1300
Timer stroke with S/T ON mm   4.4 3.9 4.9
Timer stroke with S/T OFF mm   2.9 2.6 3.2
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_04
Pump speed r/min   2150 2150 2150
Timer stroke with S/T OFF mm   6.6 6 7
Oil temperature degC   52 50 54
_05
Pump speed r/min   2500 2500 2500
Timer stroke with S/T OFF mm   6.6 6.1 7
Oil temperature degC   55 52 58
0000001201
Max. applied voltage V   16 16 16
Test voltage V   25 24 26
0000001401
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   30 29.5 30.5
Timer stroke TA mm   2.5 2.5 2.5
Timer stroke variation dT mm   0.4 0.2 0.6
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_02
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   30 29 31
Timer stroke variation dT mm   0.4 0.1 0.7
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_03
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   18 15.5 20.5
Timer stroke variation dT mm   1.2 0.8 1.6
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   0.9 0.8 1
Pre-stroke mm   0.1 0.08 0.12
Control lever angle alpha deg.   25 21 29
Control lever angle beta deg.   36 31 41

Test data Ex:

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104780-9171
Note: Potentiometer (P/M) adjustment method Substitute the actual measurement of the angle a of each I/P in the following formula and determine the P/M output adjustment y (V). When the angle a <= c: y = 7.23 When c < angle a < d: y = 7.23+( angle a -33) x 0.133 When d <alpha <e: y=7.97 Reference: Idle position and full speed position output voltages are V6 (idle) and V7 (full speed). A:Potentiometer standards B:ON, OFF switch standard G:ON-->OFF D:OFF-->ON E:Adjusting point F:Checking point P:Boost pressure Vi:Applied voltage C1:Full-speed C2:Idle Q:Injection quantity N:Pump speed V:Output voltage C:Control lever angle
----------
a=-deg c=33deg d=39deg e=-deg P1=-kPa P2=-mmHg V6=1.6+-0.6V V7=7.6+-0.4V
----------
V1=a+-0.03V V2=1.6+-0.6V V3=-V V4=-V V5=-V C3=0.1~10.2deg C4=(19.4)deg Vi=10V P1=-kPa P2=-mmHg




Have questions with 104780-9171?





Group cross 104780-9171 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T080 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 434 
167006T080 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T081 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 452 
167006T081 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T082 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 781 
167006T082 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T083 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 782 
167006T083 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
16700VJ400 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 435 
16700VJ400 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
16700VJ401 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 469 
16700VJ401 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T078 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 016 
167006T078 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

104780-9171  

104780-9172 
 
167006T079 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 783 
167006T079 
INJECTION-PUMP ASSEMBLY
TD27
9 460 613 406 
1670040K10 
INJECTION-PUMP ASSEMBLY
TD27
9 460 613 470 
1670084K03 
INJECTION-PUMP ASSEMBLY
TD27
Back to top