104780-9132 ZEXEL 9 460 614 782 BOSCH INJECTION-PUMP ASSEMBLY 9460614782 1047809132 167006t083


104780-9132 INJECTION-PUMP ASSEMBLY
Rating:
86
Buy INJECTION-PUMP ASSEMBLY 104780-9132 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 460 614 782 9460614782
ZEXEL 104780-9132 1047809132
NISSAN-DIESEL 167006T083 167006t083

Cross reference number

BOSCH 9 460 614 782 9460614782
ZEXEL 104780-9132 1047809132
NISSAN-DIESEL 167006T083 167006t083


Zexel num
Bosch num
Firm num
Name
104780-9132 
9 460 614 782 
167006T083  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
TD27 K 11CJ INJECTION PUMP ASSY VE4 VE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   44.8 44.3 45.3
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   41.8 39.3 44.3
Oil temperature degC   48 46 50
Injection timing adjustment_03
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   44.8 43.8 45.8
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   44.5 41.5 47.5
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   10.9 8.9 12.9
Basic   *
Oil temperature degC   55 52 58
Injection quantity adjustment_02
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   39.7 39.7 39.7
Oil temperature degC   52 50 54
Injection quantity adjustment_04
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   10.9 8.4 13.4
Basic   *
Oil temperature degC   55 52 58
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   7.7 5.7 9.7
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   7.7 5.2 10.2
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 45 80
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 45 80
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1100 1100 1100
Overflow quantity cm3/min   450 320 580
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1300 1300 1300
Pressure with S/T ON kPa   559 520 598
Pressure with S/T ON kgf/cm2   5.7 5.3 6.1
Pressure with S/T OFF kPa   471 442 500
Pressure with S/T OFF kgf/cm2   4.8 4.5 5.1
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
Stop lever angle_02
Pump speed r/min   1300 1300 1300
Pressure with S/T OFF kPa   471 432 510
Pressure with S/T OFF kgf/cm2   4.8 4.4 5.2
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
Stop lever angle_03
Pump speed r/min   1700 1700 1700
Pressure with S/T OFF kPa   559 520 598
Pressure with S/T OFF kgf/cm2   5.7 5.3 6.1
Oil temperature degC   50 48 52
0000001101
Pump speed r/min   1300 1300 1300
Timer stroke with S/T ON mm   4.2 3.8 4.6
Timer stroke with S/T OFF mm   2.3 2.1 2.5
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_02
Pump speed r/min   1100 1100 1100
Timer stroke with S/T OFF mm   1.4 0.9 1.9
Oil temperature degC   50 48 52
_03
Pump speed r/min   1300 1300 1300
Timer stroke with S/T ON mm   4.2 3.7 4.7
Timer stroke with S/T OFF mm   2.3 2 2.6
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_04
Pump speed r/min   1700 1700 1700
Timer stroke with S/T OFF mm   4.1 3.6 4.6
Oil temperature degC   50 48 52
_05
Pump speed r/min   2300 2300 2300
Timer stroke with S/T OFF mm   6.2 5.7 6.6
Oil temperature degC   52 50 54
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   27.8 27.3 28.3
Timer stroke TA mm   1.7 1.5 1.9
Timer stroke variation dT mm   0.6 0.6 0.6
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_02
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   27.8 26.8 28.8
Timer stroke TA mm   1.7 1.4 2
Timer stroke variation dT mm   0.6 0.6 0.6
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_03
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   16.8 14.3 19.3
Timer stroke TA mm   1.1 0.6 1.6
Timer stroke variation dT mm   1.2 1.2 1.2
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   0.9 0.8 1
Pre-stroke mm   0.1 0.08 0.12
Control lever angle alpha deg.   25 21 29
Control lever angle beta deg.   36 31 41

Test data Ex:

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104780-9132
Note: Potentiometer (P/M) adjustment method Substitute the actual measurement of the angle a of each I/P in the following formula and determine the P/M output adjustment y (V). When the angle a <= c: y = 7.23 When c < angle a < d: y = 7.23+( angle a -33) x 0.133 When d <alpha <e: y=7.97 Reference: Idle position and full speed position output voltages are V6 (idle) and V7 (full speed). The switch voltage specification is the value when the idle lever position is V8. A:Potentiometer standards B:ON, OFF switch standard G:ON-->OFF D:OFF-->ON E:Adjusting point F:Checking point P:Boost pressure Vi:Applied voltage C1:Full-speed C2:Idle Q:Injection quantity N:Pump speed V:Output voltage C:Control lever angle
----------
a=MEASURE c=33deg d=39deg e=-deg P1=-kPa P2=-mmHg V6=1.6+-0.6V V7=7.6+-0.4V V8=0V
----------
V1=a+-0.03V V2=1.6+-0.6V V3=-V V4=0.82+-0.8V V5=3.2+-0.8V C3=4.9+5.3-4.8deg C4=19.4+-5.0deg Vi=10V P1=-kPa P2=-mmHg




Have questions with 104780-9132?





Group cross 104780-9132 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T080 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 434 
167006T080 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T081 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 452 
167006T081 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T082 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 781 
167006T082 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T083 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

104780-9132  
9 460 614 782 
167006T083 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
16700VJ400 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 435 
16700VJ400 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
16700VJ401 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 613 469 
16700VJ401 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T078 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 016 
167006T078 
INJECTION-PUMP ASSEMBLY
TD27
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
167006T079 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 460 614 783 
167006T079 
INJECTION-PUMP ASSEMBLY
TD27
9 460 613 406 
1670040K10 
INJECTION-PUMP ASSEMBLY
TD27
9 460 613 470 
1670084K03 
INJECTION-PUMP ASSEMBLY
TD27
Back to top