104748-0130 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047480130 rf0113800


104748-0130 INJECTION-PUMP ASSEMBLY
Rating:
11
Buy INJECTION-PUMP ASSEMBLY 104748-0130 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104748-0130 1047480130
MAZDA RF0113800 rf0113800

Cross reference number

ZEXEL 104748-0130 1047480130
MAZDA RF0113800 rf0113800


Zexel num
Bosch num
Firm num
Name
104748-0130 
104748-0139 
 
RF0113800  MAZDA
INJECTION-PUMP ASSEMBLY
RF *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1375 1375 1375
Average injection quantity mm3/st.   35.8 35.3 36.3
Difference in delivery mm3/st.   2.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   11 8 14
Injection timing adjustment_03
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   21.1 18.1 24.1
Injection timing adjustment_04
Pump speed r/min   2325 2325 2325
Average injection quantity mm3/st.   31.7 29.7 33.7
Injection timing adjustment_05
Pump speed r/min   1375 1375 1375
Average injection quantity mm3/st.   35.8 34.8 36.8
Injection timing adjustment_06
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   27.9 25.9 29.9
Injection quantity adjustment
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   21.1 19.1 23.1
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   4
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   8 6 10
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   8 6 10
Governor adjustment_03
Pump speed r/min   450 450 450
Average injection quantity mm3/st.   3
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   42 42
Basic   *
Speed control lever angle
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1375 1375 1375
Overflow quantity cm3/min   410 278 542
Stop lever angle
Pump speed r/min   1375 1375 1375
Pressure kPa   460.5 431 490
Pressure kgf/cm2   4.7 4.4 5
Basic   *
Stop lever angle_02
Pump speed r/min   500 500 500
Pressure kPa   215.5 186 245
Pressure kgf/cm2   2.2 1.9 2.5
Stop lever angle_03
Pump speed r/min   1375 1375 1375
Pressure kPa   460.5 431 490
Pressure kgf/cm2   4.7 4.4 5
Stop lever angle_04
Pump speed r/min   2325 2325 2325
Pressure kPa   706 677 735
Pressure kgf/cm2   7.2 6.9 7.5
0000001101
Pump speed r/min   1375 1375 1375
Timer stroke mm   4.7 4.5 4.9
Basic   *
_02
Pump speed r/min   1375 1375 1375
Timer stroke mm   4.7 4.4 5
_03
Pump speed r/min   2000 2000 2000
Timer stroke mm   8 7.4 8.6
_04
Pump speed r/min   2325 2325 2325
Timer stroke mm   9.7 9.1 10.3
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1375 1375 1375
Average injection quantity mm3/st.   28.2 27.2 29.2
Timer stroke TA mm   4.1 3.9 4.3
Basic   *
_02
Pump speed r/min   1375 1375 1375
Average injection quantity mm3/st.   28 26.5 29.5
Timer stroke TA mm   4.1 3.8 4.4
_03
Pump speed r/min   1375 1375 1375
Average injection quantity mm3/st.   16 14.5 17.5
Timer stroke TA mm   2.9 2.2 3.6
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.5 1.4 1.6
Control lever angle alpha deg.   30 26 34
Control lever angle beta deg.   45 40 50

Test data Ex:

0000001801 M-CSD ADJUSTMENT

Test data 104748-0130
M-CSD adjustment 1. Fixing the M-CSD (1)At roller holder advance angle a adjust the lever shaft ball pin so that it contacts the roller holder. (2)At this time, adjust the position of the M-CSD lever (A) using adjusting screw (C) so that the clearance between the M-CSD lever (A) and the stopper (B) becomes L1. Then fix using nut (D). 2. M-FICD adjustment (1)Move the CSD lever (A) through its full stroke. (2)Adjust screw (E) so that the control lever (G)'s position is b (the clearance between the control lever and the idling set screw is L2). Then fix using the nut (F).
----------
L1=0.5+2mm L2=4.8+-1mm a=0deg b=7deg
----------
L1=0.5+2mm L2=4.8+-1mm T=-N-m(-kgf-m) b=7deg




Have questions with 104748-0130?





Group cross 104748-0130 ZEXEL

Mazda 

104748-0130  

104748-0139 
 
RF0113800 
INJECTION-PUMP ASSEMBLY
RF
 
RF0113800B 
INJECTION-PUMP ASSEMBLY
RF
 
 
INJECTION-PUMP ASSEMBLY
RF
9 460 610 143 
RF0113800C 
INJECTION-PUMP ASSEMBLY
RF
9 460 610 188 
 
INJECTION-PUMP ASSEMBLY
RF
9 460 610 304 
 
INJECTION-PUMP ASSEMBLY
RF
9 460 612 544 
 
INJECTION-PUMP ASSEMBLY
9 460 612 545 
 
INJECTION-PUMP ASSEMBLY
RF

Mazda 

9 460 612 545 
RF0113800F 
INJECTION-PUMP ASSEMBLY
RF
9 460 612 035 
 
INJECTION-PUMP ASSEMBLY

Mazda 

9 460 611 261 
RF0113800F 
INJECTION-PUMP ASSEMBLY
RF
Back to top