Rating:
Information injection-pump assembly
ZEXEL
104742-4000
1047424000
NISSAN-DIESEL
1670001T01
1670001t01
Cross reference number
ZEXEL
104742-4000
1047424000
NISSAN-DIESEL
1670001T01
1670001t01
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
66.5
66
67
Difference in delivery
mm3/st.
4
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_02
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
60
56.5
63.5
Oil temperature
degC
50
48
52
Injection timing adjustment_03
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
66.5
65.5
67.5
Difference in delivery
mm3/st.
4
Oil temperature
degC
50
48
52
Injection timing adjustment_04
Pump speed
r/min
1750
1750
1750
Average injection quantity
mm3/st.
65.7
60.2
71.2
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
2050
2050
2050
Average injection quantity
mm3/st.
27.4
24.4
30.4
Difference in delivery
mm3/st.
7
Basic
*
Oil temperature
degC
52
50
54
Injection quantity adjustment_02
Pump speed
r/min
2200
2200
2200
Average injection quantity
mm3/st.
5
Oil temperature
degC
52
50
54
Injection quantity adjustment_03
Pump speed
r/min
2050
2050
2050
Average injection quantity
mm3/st.
27.4
23.9
30.9
Oil temperature
degC
52
50
54
Governor adjustment
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
16.1
14.1
18.1
Difference in delivery
mm3/st.
2.5
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
16.1
13.6
18.6
Difference in delivery
mm3/st.
3.5
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
70
70
110
Basic
*
Oil temperature
degC
48
46
50
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
70
70
110
Oil temperature
degC
48
46
50
Speed control lever angle
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
Speed control lever angle_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
160
30
290
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
1400
1400
1400
Pressure
kPa
530
501
559
Pressure
kgf/cm2
5.4
5.1
5.7
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
1000
1000
1000
Pressure
kPa
392
353
431
Pressure
kgf/cm2
4
3.6
4.4
Oil temperature
degC
50
48
52
Stop lever angle_03
Pump speed
r/min
1400
1400
1400
Pressure
kPa
530
491
569
Pressure
kgf/cm2
5.4
5
5.8
Oil temperature
degC
50
48
52
Stop lever angle_04
Pump speed
r/min
1750
1750
1750
Pressure
kPa
657
618
696
Pressure
kgf/cm2
6.7
6.3
7.1
Oil temperature
degC
50
48
52
0000001101
Pump speed
r/min
1400
1400
1400
Timer stroke
mm
2.5
2.3
2.7
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1
0.4
1.6
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1400
1400
1400
Timer stroke
mm
2.5
2.1
2.9
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
1750
1750
1750
Timer stroke
mm
4.1
3.5
4.7
Oil temperature
degC
50
48
52
0000001201
Max. applied voltage
V
16
16
16
Test voltage
V
25
24
26
Timing setting
K dimension
mm
3.1
3
3.2
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
0.7
0.6
0.8
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
36
31
41
Test data Ex:
0000001801 MICROSWITCH ADJUSTMENT
Microswitch adjustment
Insert a block gauge thickness L (corresponding to a) between the idle set screw and the control lever and set the microswitch using the adjusting screw so that it moves from ON to OFF.
----------
L=3.3mm a=5deg
----------
----------
L=3.3mm a=5deg
----------