Rating:
Information injection-pump assembly
ZEXEL
104740-1670
1047401670
ISUZU
8943105540
8943105540
Cross reference number
ZEXEL
104740-1670
1047401670
ISUZU
8943105540
8943105540
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
52.2
51.7
52.7
Difference in delivery
mm3/st.
4
Basic
*
Remarks
Full
Full
Injection timing adjustment_02
Pump speed
r/min
750
750
750
Boost pressure
kPa
22.85
21.7
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
45.3
44.8
45.8
Difference in delivery
mm3/st.
3.5
Basic
*
Remarks
CBS
CBS
Injection timing adjustment_03
Pump speed
r/min
2600
2600
2600
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
15.6
14.1
17.1
Injection timing adjustment_04
Pump speed
r/min
2250
2250
2250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
42.4
38.9
45.9
Injection timing adjustment_05
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
52.2
51.2
53.2
Remarks
Full
Full
Injection timing adjustment_06
Pump speed
r/min
750
750
750
Boost pressure
kPa
22.85
21.7
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
45.3
44.3
46.3
Remarks
CBS
CBS
Injection timing adjustment_07
Pump speed
r/min
600
600
600
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
39.7
36.2
43.2
Injection quantity adjustment
Pump speed
r/min
2600
2600
2600
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
15.6
14.6
16.6
Difference in delivery
mm3/st.
3
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2800
2800
2800
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
3
Governor adjustment
Pump speed
r/min
425
425
425
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
11.3
9.3
13.3
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
425
425
425
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
11.3
9.3
13.3
Governor adjustment_03
Pump speed
r/min
700
700
700
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
65
55
75
Basic
*
Speed control lever angle
Pump speed
r/min
425
425
425
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Overflow quantity
cm3/min
399
270
528
Stop lever angle
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Pressure
kPa
470.5
451
490
Pressure
kgf/cm2
4.8
4.6
5
Basic
*
Stop lever angle_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Pressure
kPa
470.5
451
490
Pressure
kgf/cm2
4.8
4.6
5
Stop lever angle_03
Pump speed
r/min
2100
2100
2100
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Pressure
kPa
676.5
647
706
Pressure
kgf/cm2
6.9
6.6
7.2
0000001101
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Timer stroke
mm
2.7
2.5
2.9
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Timer stroke
mm
2.7
2.4
3
_03
Pump speed
r/min
1750
1750
1750
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Timer stroke
mm
4.8
4.2
5.4
_04
Pump speed
r/min
2100
2100
2100
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Timer stroke
mm
6.2
5.8
6.6
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
39
38.5
39.5
Timer stroke variation dT
mm
0.6
0.4
0.8
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
39
38
40
Timer stroke variation dT
mm
0.6
0.3
0.9
_03
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
64
62.7
65.3
Boost pressure
mmHg
480
470
490
Average injection quantity
mm3/st.
25
23.5
26.5
Timer stroke variation dT
mm
1.2
0.7
1.7
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.2
1.1
1.3
BCS stroke
mm
4
3.9
4.1
Control lever angle alpha
deg.
-10
-14
-6
Control lever angle beta
deg.
37
32
42
Test data Ex:
0000001801 A/T PLATE ADJUSTMENT
A/T plate adjustment
1. Turn the control lever from the idle position (B) to the Full speed position (C)
2. Adjust the A/T plate (D) so that (A)(C) - (A)(B) = L3, then fix.
----------
L3=33+-0.5mm
----------
L1=91.5mm L2=90.5mm L3=33+-0.5mm T=3.5~5N-m(0.35~0.5kgf-m)
----------
L3=33+-0.5mm
----------
L1=91.5mm L2=90.5mm L3=33+-0.5mm T=3.5~5N-m(0.35~0.5kgf-m)