Rating:
Information injection-pump assembly
ZEXEL
103662-1810
1036621810
0429110820
Cross reference number
ZEXEL
103662-1810
1036621810
0429110820
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle
105011-9210
Nozzle holder
105043-3000
Opening pressure
MPa
34.3
Opening pressure
kgf/cm2
350
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2.4-1124
Outer diameter - inner diameter - length (mm) mm 6-2.4-1124
Overflow valve
132424-0620
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
2.05
2
2.1
Rack position
Point A R=A
Point A R=A
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
14
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
400
390
410
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the rack
*
Remarks
Standard point A's rack position same as row R
Standard point A's rack position same as row R
Injection quantity adjustment_02
Adjusting point
B
Rack position
10
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
240
228
252
Max. variation between cylinders
%
0
-5
5
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
7.5+-0.5
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
68
61.2
74.8
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Idle sub spring setting: L1.
----------
K=15 L1=4.5-0.5mm
----------
----------
K=15 L1=4.5-0.5mm
----------
Speed control lever angle
F:Full speed
S:Stop
----------
----------
a=11.5deg+-5deg b=30deg+-5deg
----------
----------
a=11.5deg+-5deg b=30deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
I:Idle
(1)The clearance must be aa (at normal).
----------
aa=(0.8mm)
----------
a=30deg+-5deg b=21.5deg+-5deg c=12deg+-5deg
----------
aa=(0.8mm)
----------
a=30deg+-5deg b=21.5deg+-5deg c=12deg+-5deg