101692-9290 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016929290


101692-9290 INJECTION-PUMP ASSEMBLY
Rating:
70
Buy INJECTION-PUMP ASSEMBLY 101692-9290 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101692-9290 1016929290

Service parts 101692-9290 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101069-3740
3. GOVERNOR 105401-0380
4. SUPPLY PUMP 105220-7050
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105661-0401
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-6690
11. Nozzle and Holder 16600-Z5519
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105031-4650
14. NOZZLE 105015-6380
15. NOZZLE SET

Include in #1:

101692-9290 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101692-9290 1016929290


Zexel num
Bosch num
Firm num
Name
101692-9290 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.4 3.35 3.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.5 60.5
Difference between angles 2
Cyl.1-2
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cal 1-3
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-5
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   13.6
Pump speed r/min   750 750 750
Average injection quantity mm3/st.   83 81 85
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the lever   *
Boost pressure kPa   24 24
Boost pressure mmHg   180 180
Injection quantity adjustment_02
Adjusting point   B
Rack position   R1(12.3)
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   59.7 58.7 60.7
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_03
Adjusting point   C
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   8 6.2 9.8
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   550 550 550
Rack position   R1(12.3)
Boost pressure kPa   4 2.7 5.3
Boost pressure mmHg   30 20 40
Boost compensator adjustment_02
Pump speed r/min   550 550 550
Rack position   13.6
Boost pressure kPa   10.7 10.7 10.7
Boost pressure mmHg   80 80 80

Test data Ex:

Governor adjustment

Test data 101692-9290
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm. (3)When excess fuel lever for starting operates (at boost pressure 0): SXL (4)Boost compensator stroke (5)Set idle sub-spring (6)Main spring setting
----------
K=7 SXL=16.2+-0.1mm
----------

Speed control lever angle

Test data 101692-9290
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=(4deg)+-5deg b=(14deg)+-5deg

Stop lever angle

Test data 101692-9290
N:Pump normal S:Stop the pump. (1)Normal
----------

----------
a=26.5deg+-5deg b=53deg+-5deg

0000001101

Test data 101692-9290
N:Normal B:When boosted (1)Rack position = aa (point D) at boost pressure 0.
----------
aa=16.2+-0.1mm
----------
a=(15deg) b=(30deg)

0000001501 GOV FULL LOAD ADJUSTMENT

Test data 101692-9290
Title1:Full load stopper adjustment Title2:Governor set speed LABEL1:Distinguishing LABEL2:Pump speed (r/min) LABEL3:Ave. injection quantity (mm3/st) LABEL4:Max. var. bet. cyl. LABEL5:Remarks LABEL6:Distinguishing LABEL7:Governor set speed (r/min) LABEL8:Maximum no-load speed (r/min) LABEL9:Remarks (1)Adjustment conditions are the same as those for measuring injection quantity. (2)At high idle rack position L
----------
L=9.5mm
----------
a1=A a2=B a3=C a4=- a5=- a6=- r1=750r/min r2=750r/min r3=750r/min r4=- r5=- r6=- Q1=86.5+-2mm3/st Q2=83+-2mm3/st Q3=76+-2mm3/st Q4=- Q5=- Q6=- c1=+-3.5% c2=+-3.5% c3=+-3.5% c4=- c5=- c6=- a7=25 a8=24 a9=23 a10=22 a11=21 a12=20 a13=19 a14=18 a15=17 a16=16 a17=15 a18=14 a19=- a20=- a21=- a22=- a23=- a24=- a25=- a26=- a27=- a28=- r7=1250r/min r8=1200r/min r9=1150r/min r10=1100r/min r11=1050r/min r12=1000r/min r13=950r/min r14=900r/min r15=850r/min r16=800r/min r17=750r/min r18=700r/min r19=- r20=- r21=- r22=- r23=- r24=- r25=- r26=- r27=- r28=- R7=1340+-31r/min R8=1290+-30r/min R9=1235+-28r/min R10=1180+-27r/min R11=1130+-26r/min R12=1075+-25r/min R13=1020+-23r/min R14=965+-22r/min R15=915+-22r/min R16=860+-20r/min R17=805+-18r/min R18=750+-17r/min R19=- R20=- R21=- R22=- R23=- R24=- R25=- R26=- R27=- R28=-

Timing setting

Test data 101692-9290
(1)Pump vertical direction (2)Position of coupling's threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(60deg)




Have questions with 101692-9290?





Group cross 101692-9290 ZEXEL

Yanmar 

 
12367851010 
INJECTION-PUMP ASSEMBLY
6MD
 
12367851011 
INJECTION-PUMP ASSEMBLY
6DH
 
EWV9012 
INJECTION-PUMP ASSEMBLY
 
EWV9060 
INJECTION-PUMP ASSEMBLY

Mitsubishi-Heav 

 
3686109010 
INJECTION-PUMP ASSEMBLY
S6F
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 616 062 
16790Z5574 
INJECTION-PUMP ASSEMBLY
FE6T04
101692-9290  
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 616 063 
16790Z5575 
INJECTION-PUMP ASSEMBLY
FE6T04
Back to top