Rating:
Information injection-pump assembly
ZEXEL
101672-2480
1016722480
HINO
220201111A
220201111a
Service parts 101672-2480 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
7.
COUPLING PLATE
8.
_
9.
_
10.
NOZZLE AND HOLDER ASSY
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
13.
NOZZLE-HOLDER
15.
NOZZLE SET
Include in #1:
101672-2480
as INJECTION-PUMP ASSEMBLY
Include in #2:
104740-8740
as _
Cross reference number
ZEXEL
101672-2480
1016722480
HINO
220201111A
220201111a
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
2.1
2.05
2.15
Rack position
After adjusting injection quantity. R=A
After adjusting injection quantity. R=A
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.5 60.5
Cal 1-4 deg. 60 59.5 60.5
Difference between angles 2
Cyl.1-2 deg. 120 119.5 120.5
Cyl.1-2 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cal 1-3 deg. 240 239.5 240.5
Cal 1-3 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-5 deg. 300 299.5 300.5
Cal 1-5 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
14.3
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
90.5
88.9
92.1
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
11.5
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
62.2
60.4
64
Max. variation between cylinders
%
0
-3
3
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
7.8+-0.5
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
15.8
13.2
18.4
Max. variation between cylinders
%
0
-13
13
Fixing the rack
*
Injection quantity adjustment_04
Adjusting point
D
Rack position
14.8
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
92
88.7
95.3
Max. variation between cylinders
%
0
-4
4
Fixing the rack
*
Injection quantity adjustment_05
Adjusting point
E
Rack position
14.3+-0.
5
Pump speed
r/min
950
950
950
Average injection quantity
mm3/st.
94.5
91.2
97.8
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK CAP: R1
----------
K=10 R1=(17.5)mm
----------
----------
K=10 R1=(17.5)mm
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
(1)Stopper bolt setting
----------
----------
a=6deg+-5deg b=32deg+-3deg c=23deg+-5deg
----------
----------
a=6deg+-5deg b=32deg+-3deg c=23deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Normal
----------
----------
a=(19deg) b=(34deg)
----------
----------
a=(19deg) b=(34deg)
Timing setting
(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)After adjusting the injection quantity, adjust at rack position aa.
(4)-
----------
aa=14.3mm
----------
a=(40deg)
----------
aa=14.3mm
----------
a=(40deg)