101607-6100 ZEXEL F 01G 09U 05H BOSCH INJECTION-PUMP ASSEMBLY f01g09u05h 1016076100


101607-6100 INJECTION-PUMP ASSEMBLY
Rating:
46
Buy INJECTION-PUMP ASSEMBLY 101607-6100 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 01G 09U 05H f01g09u05h
ZEXEL 101607-6100 1016076100

Include in #1:

Cross reference number

BOSCH F 01G 09U 05H f01g09u05h
ZEXEL 101607-6100 1016076100


Zexel num
Bosch num
Firm num
Name
101607-6100 
101607-6101 
F 01G 09U 05H 
   
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.2 4.15 4.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.2
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   70.9 68.8 73
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   11.6 9.9 13.3
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.2)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   70.9 69.9 71.9
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.15
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   85.2 81.2 89.2
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.5
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   64.9 60.9 68.9
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   102 102 112
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1200--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1150
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1350
Advance angle deg.   2.5 2 3
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-6100
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=H21
----------

Speed control lever angle

Test data 101607-6100
F:Full speed I:Idle (1)Stopper bolt setting (2)Use the hole at R = aa (3)Accelerator lever
----------
aa=40mm
----------
a=18.5deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101607-6100
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at speed = aa and rack position = bb. Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (actual measurement; non-injection rack position). (3)Rack position = approximately ee. (4)Free (at delivery)
----------
aa=1450r/min bb=6.6-0.5mm cc=275r/min dd=- ee=17.4mm
----------
a=38.5deg+-5deg b=(27deg) c=17deg+-5deg

Timing setting

Test data 101607-6100
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(1deg)




Have questions with 101607-6100?





Group cross 101607-6100 ZEXEL

101607-6100  

101607-6101 
F 01G 09U 05H 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 05J 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 671 
ME076450 
INJECTION-PUMP ASSEMBLY
6D16TD2
9 400 615 672 
ME076451 
INJECTION-PUMP ASSEMBLY
6D16TD1
9 400 615 673 
ME076996 
INJECTION-PUMP ASSEMBLY
6D17
 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 05K 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 674 
ME076991 
INJECTION-PUMP ASSEMBLY
6D16
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 675 
ME076921 
INJECTION-PUMP ASSEMBLY
6D17
F 019 Z10 374 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 375 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 376 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 676 
ME076986 
INJECTION-PUMP ASSEMBLY
6D14
 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 377 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 378 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 379 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 380 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 677 
ME076992 
INJECTION-PUMP ASSEMBLY
6D16
F 019 Z10 381 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 382 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 383 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 384 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 385 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 678 
ME076997 
INJECTION-PUMP ASSEMBLY
6D17
9 400 615 679 
ME076985 
INJECTION-PUMP ASSEMBLY
6D14
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 680 
ME076987 
INJECTION-PUMP ASSEMBLY
6D14
Back to top