101607-1212 ZEXEL F 01G 09U 056 BOSCH INJECTION-PUMP ASSEMBLY f01g09u056 1016071212


101607-1212 INJECTION-PUMP ASSEMBLY
Rating:
15
Buy INJECTION-PUMP ASSEMBLY 101607-1212 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 01G 09U 056 f01g09u056
ZEXEL 101607-1212 1016071212

Include in #2:

Cross reference number

BOSCH F 01G 09U 056 f01g09u056
ZEXEL 101607-1212 1016071212


Zexel num
Bosch num
Firm num
Name
101607-1212 
101607-1213 
F 01G 09U 056 
   
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.6
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   72.5 70.3 74.7
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   8.3 7.1 9.5
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.6)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   72.5 71.5 73.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.15
Pump speed r/min   1400 1400 1400
Average injection quantity mm3/st.   79.5 75.5 83.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.65
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   71.5 67.5 75.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   14.8+-0. 2
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   120 100 140
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1150
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.9 0.4 1.4
Timer adjustment_03
Pump speed r/min   1380
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-1212
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT: RAL
----------
T1=F14 RAL=14.8+-0.2mm
----------

Speed control lever angle

Test data 101607-1212
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=41deg+-5deg b=(40deg)+-3deg

Stop lever angle

Test data 101607-1212
N:Pump normal S:Stop the pump. (1)Pump speed = aa and rack position = bb (non-injection rack position) (2)Set the stopper bolt (confirm non-injection).
----------
aa=1400r/min bb=6.9-0.5mm
----------
a=32.5deg+-5deg b=25deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

0000001601 TAMPER PROOF

Test data 101607-1212
1. Method for setting tamperproof proofing (1)After governor adjustment (torque cam phase adjustment), move the load lever to increase the full rack position to Ra. (2)At speed N1 screw in screw (A) to obtain the rack position (actual measurement: Rb) for injection quantity Q1. (3)Temporarily caulk using the tip of a screwdriver (4)Confirm that the rack at that time is at Rc. (5)Lock using setscrew (B). (Tightening torque = T) (6)Next, coat (C) with adhesive and then pressfit. (7)Then, readjust the full rack position using the load lever.
----------
N1=850r/min Q1=78.3+-1mm3/st Ra=(0.4)mm Rb=R2mm Rc=R2mm
----------
T=3.4~4.9N-m(0.35~0.5Kgf-m)

0000001701 LEVER

Test data 101607-1212
(A) Accelerator lever stopper bolt (B) Link (c) Nut (D) Lever (E) Pin (f) lever (G) Stopper bolt (H) Return spring (J) Pin (E) contacts lever. (K) Load sensor terminal (1)Black (2)Blue-yellow (3)Blue-red Setting the accelerator lever angle, load sensor adjustment 1. Accelerator lever setting method (1)Position the speed lever against the idle stopper bolt and fix. (2)Screw in the accelerator lever stopper bolt (A) and back off the stopper bolt (A) from the position where the accelerator lever pin contacts the speed lever and set. (Gap: approx. 1 mm) Tightening torque: 4.9~7 N.m {0.5~0.7 kgf.m} 2. Load sensor adjustment (See fig 1) (1)Load sensor output measuring circuit Apply DC5+-0.01V to the load sensor terminals and measure the output voltage. (2)Load sensor output adjustment procedure Hold the speed lever against the full side stopper bolt and fix. Adjust the load sensor output voltage to VF = 0.417+-0.1 V using the link (B) and then fix temporarily using nut (C). Turn the speed lever from the idle side to the full side and confirm that output voltage VF = 0.417+-0.1 V is obtained. Confirm several times and then fix using nut (C). Tightening torque: 3.4~4.9 N.m {0.35~0.5 kgf.m} 3. Setting the step motor's idle side stopper bolt After adjustment in previous 1 and 2, position speed lever against idle stopper bolt and fix. Then, screw in stopper bolt G until step motor lever D's pin E contacts lever F. Back off 10+2 deg (approx. 3.5 mm) from this position and fix G. (See fig. 3) 4. Speed lever return confirmation (1)Remove return spring (H) and confirm that the speed lever is returned to the idle position by the torsion spring. (2)Reinstall the return spring (H) in its original position.
----------

----------

Timing setting

Test data 101607-1212
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(0deg)




Have questions with 101607-1212?





Group cross 101607-1212 ZEXEL

Mitsubishi 

9 400 615 599 
ME086627 
INJECTION-PUMP ASSEMBLY
6D31
F 01G 09U 055 
 
INJECTION-PUMP ASSEMBLY
101607-1212  

101607-1213 
F 01G 09U 056 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 600 
ME076622 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 601 
ME086628 
INJECTION-PUMP ASSEMBLY
6D31
9 400 615 602 
ME086629 
INJECTION-PUMP ASSEMBLY
6D31
 
ME086634 
INJECTION-PUMP ASSEMBLY
6D31
9 400 615 603 
ME9H6126A 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 604 
ME9H6126B 
INJECTION-PUMP ASSEMBLY
6D15T2
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 605 
ME076610 
INJECTION-PUMP ASSEMBLY
6D16
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME047807 
INJECTION-PUMP ASSEMBLY
6D16T
9 400 615 606 
ME056886 
INJECTION-PUMP ASSEMBLY
6D22
Back to top