101606-6741 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016066741 me076548


101606-6741 INJECTION-PUMP ASSEMBLY
Rating:
82
Buy INJECTION-PUMP ASSEMBLY 101606-6741 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101606-6741 1016066741
MITSUBISHI ME076548 me076548

Cross reference number

ZEXEL 101606-6741 1016066741
MITSUBISHI ME076548 me076548


Zexel num
Bosch num
Firm num
Name
101606-6741 
101607-1060 
 
ME076548  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D16 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.2 4.15 4.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.3
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   74.5 72.3 76.7
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   8 6.8 9.2
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.3)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   74.5 73.5 75.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.1
Pump speed r/min   1400 1400 1400
Average injection quantity mm3/st.   83.5 79.5 87.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.4
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   69 65 73
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   146 136 156
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1150
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.9 0.4 1.4
Timer adjustment_03
Pump speed r/min   1380
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101606-6741
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=E45
----------

Speed control lever angle

Test data 101606-6741
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101606-6741
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at pump speed = aa and rack position = bb (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (non-injection rack position).
----------
aa=1400r/min bb=6.5-0.5mm cc=275r/min dd=(8.5)-0.5mm
----------
a=11.5deg+-5deg b=27deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

0000001601 LEVER

Test data 101606-6741
(A) Idle (B) Full speed (C) Base lever (D) Accelerator lever (E) Accelerator lever delivery position 1. Measure speed lever angle (1)Measure the angle when the accelerator lever (D) contacted the base lever (C) at a.
----------

----------
b=27deg+-5deg c=11.5deg+-5deg

Timing setting

Test data 101606-6741
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(1deg)




Have questions with 101606-6741?





Group cross 101606-6741 ZEXEL

Mitsubishi 

9 400 615 534 
ME056839 
INJECTION-PUMP ASSEMBLY
6D22
9 400 615 535 
ME076518 
INJECTION-PUMP ASSEMBLY
6D16
 
ME076546 
INJECTION-PUMP ASSEMBLY
6D15T2
F 01G 09U 04M 
ME076547 
INJECTION-PUMP ASSEMBLY
6D15T2
101606-6741  

101607-1060 
 
ME076548 
INJECTION-PUMP ASSEMBLY
6D16
 
ME076550 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 536 
ME086588 
INJECTION-PUMP ASSEMBLY
6D31
 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 006 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 610 708 
ME076572 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 537 
ME157190 
INJECTION-PUMP ASSEMBLY
6D22
F 01G 09U 04N 
ME076551 
INJECTION-PUMP ASSEMBLY
6D16
Back to top