101606-6260 ZEXEL 9 400 615 501 BOSCH INJECTION-PUMP ASSEMBLY 9400615501 1016066260 me076346


101606-6260 INJECTION-PUMP ASSEMBLY
Rating:
31
Buy INJECTION-PUMP ASSEMBLY 101606-6260 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 615 501 9400615501
ZEXEL 101606-6260 1016066260
MITSUBISHI ME076346 me076346

Service parts 101606-6260 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-9800
3. GOVERNOR 105931-5911
4. SUPPLY PUMP 105210-4641
5. AUTOM. ADVANCE MECHANIS 105643-0160
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-6030
11. Nozzle and Holder ME035655
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-3900
14. NOZZLE 105015-5700
15. NOZZLE SET

Include in #1:

101606-6260 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

BOSCH 9 400 615 501 9400615501
ZEXEL 101606-6260 1016066260
MITSUBISHI ME076346 me076346


Zexel num
Bosch num
Firm num
Name
101606-6260 
101607-1380 
9 400 615 501 
ME076346  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14 K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.8
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   65 63 67
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   10.5 9 12
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.8)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   65 64 66
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(10.8)
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   77.5 75.5 79.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.4
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   59.7 55.7 63.7
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   14.1+-0. 5
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   90 70 110
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   900--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   850
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   900
Advance angle deg.   0.8
Timer adjustment_04
Pump speed r/min   1200
Advance angle deg.   2.6 2.1 3.1
Timer adjustment_05
Pump speed r/min   1500
Advance angle deg.   5.5 5 6
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101606-6260
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=D39
----------

Speed control lever angle

Test data 101606-6260
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=10deg+-5deg b=42deg+-3deg

Stop lever angle

Test data 101606-6260
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at pump speed = aa and rack position = bb (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (non-injection rack position). (3)Rack position = approximately ee. (4)Free (at shipping)
----------
aa=1550r/min bb=7.2-0.5mm cc=275r/min dd=8.2mm ee=17.4mm
----------
a=38.5deg+-5deg b=(27deg) c=17deg+-5deg

Timing setting

Test data 101606-6260
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=16deg
----------
a=(1deg)




Have questions with 101606-6260?





Group cross 101606-6260 ZEXEL

Mitsubishi 

9 400 615 496 
ME076291 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 497 
ME076335 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 498 
ME076007 
INJECTION-PUMP ASSEMBLY
6D16
 
ME076344 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 499 
ME056788 
INJECTION-PUMP ASSEMBLY
6D22
9 400 615 500 
ME086578 
INJECTION-PUMP ASSEMBLY
6D31T
101606-6260  

101607-1380 
9 400 615 501 
ME076346 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 502 
ME076347 
INJECTION-PUMP ASSEMBLY
6D14
F 01G 09U 04J 
ME076348 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 503 
ME076349 
INJECTION-PUMP ASSEMBLY
6D14
Back to top