101605-0160 ZEXEL 9 400 612 366 BOSCH INJECTION-PUMP ASSEMBLY 9400612366 1016050160 1156034270


101605-0160 INJECTION-PUMP ASSEMBLY
Rating:
38
Buy INJECTION-PUMP ASSEMBLY 101605-0160 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 612 366 9400612366
ZEXEL 101605-0160 1016050160
ISUZU 1156034270 1156034270

Service parts 101605-0160 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101062-8500
3. GOVERNOR 105964-0070
4. SUPPLY PUMP 105220-6640
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156643-4820
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105160-5241
11. Nozzle and Holder 1-15300-421-0
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105030-4750
14. NOZZLE 105025-3730
15. NOZZLE SET

Include in #1:

101605-0160 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

BOSCH 9 400 612 366 9400612366
ZEXEL 101605-0160 1016050160
ISUZU 1156034270 1156034270


Zexel num
Bosch num
Firm num
Name
101605-0160 
101605-0161 
9 400 612 366 
1156034270  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1-T * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-4120
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED4 control unit part number   407915-0 590
RED4 rack sensor specifications mm   19
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.2 4.15 4.25
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Rack position   (10)
PWM %   44.4
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   100 98.5 101.5
Max. variation between cylinders %   0 -2 2
Basic   *
Injection quantity adjustment_02
Rack position   (7.2)
PWM %   28.9+-2. 8
Pump speed r/min   450 450 450
Average injection quantity mm3/st.   14.5 13.2 15.8
Max. variation between cylinders %   0 -14 14
Injection quantity adjustment_03
Rack position   -
PWM %   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   105 100 110
Rack limit   *

Test data Ex:

Speed control lever angle

Test data 101605-0160
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg

0000000901

Test data 101605-0160
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=9deg
----------
a=(100deg)

Stop lever angle

Test data 101605-0160
(PWM) Pulse width modulation (%) (R) Rack position (mm) Rack sensor output characteristics 1. Rack limit adjustment (1)Measure the rack position R2 for PWM a2%. (2)Confirm that it is within the range R2 = 15+-1 mm. (3)Measure the rack position R1 at PWM a %. (4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm. 2. Check the limp home operation. (1)Move the switch box's limp home switch to the limp home side. (2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table. 3. Check the pull down operation. (1)Confirm that the rack position is 19 mm at PWM B%. (2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5% B=95%
----------




Have questions with 101605-0160?





Group cross 101605-0160 ZEXEL

Isuzu 

9 400 612 260 
1156033960 
INJECTION-PUMP ASSEMBLY
6BG1-T
F 019 Z10 729 
1156033980 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 166 
1156033981 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 614 
1156034040 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 611 995 
1156034050 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 261 
1156034030 
INJECTION-PUMP ASSEMBLY
6BG1-T
F 019 Z10 730 
1156034220 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 365 
1156034221 
INJECTION-PUMP ASSEMBLY
6BG1-T
101605-0160  

101605-0161 
9 400 612 366 
1156034270 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 615 
1156034271 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 367 
1156034310 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 997 
1156034350 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 615 320 
1156034510 
INJECTION-PUMP ASSEMBLY
6BG1-T
Back to top