101603-6800 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016036800 me035799


101603-6800 INJECTION-PUMP ASSEMBLY
Rating:
10
Buy INJECTION-PUMP ASSEMBLY 101603-6800 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-6800 1016036800
MITSUBISHI ME035799 me035799

Cross reference number

ZEXEL 101603-6800 1016036800
MITSUBISHI ME035799 me035799


Zexel num
Bosch num
Firm num
Name
101603-6800 
 
ME035799  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14T * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3 2.95 3.05
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.1
Pump speed r/min   800 800 800
Each cylinder's injection qty mm3/st.   88 85.4 90.6
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   10.5 9 12
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.1)
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   88 87 89
Basic   *
Fixing the lever   *
Boost pressure kPa   49.3 49.3
Boost pressure mmHg   370 370
Injection quantity adjustment_04
Adjusting point   C
Rack position   (R1-0.8)
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   67 65 69
Fixing the lever   *
Boost pressure kPa   18.7 18.7 18.7
Boost pressure mmHg   140 140 140
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   110 90 130
Fixing the lever   *
Rack limit   *
Boost compensator adjustment
Pump speed r/min   700 700 700
Rack position   R1-1.1
Boost pressure kPa   13.3 13.3 13.3
Boost pressure mmHg   100 100 100
Boost compensator adjustment_02
Pump speed r/min   700 700 700
Rack position   (R1-0.8)
Boost pressure kPa   18.7 17.4 20
Boost pressure mmHg   140 130 150
Boost compensator adjustment_03
Pump speed r/min   700 700 700
Rack position   R1(12.1)
Boost pressure kPa   36 29.3 42.7
Boost pressure mmHg   270 220 320

Test data Ex:

Governor adjustment

Test data 101603-6800
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT (3)Boost compensator stroke: BCL
----------
T1=B44 BCL=1.1+-0.1mm
----------

Timer adjustment

Test data 101603-6800
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C3=(8)deg t1=2--sec. t2=2--sec.
----------
N1=1400r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=0.5--deg C2=8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 101603-6800
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=(41deg)+-3deg

Stop lever angle

Test data 101603-6800
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at speed = rated point and rack position = bb. Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed = cc. (3)Rack position = approximately aa. (4)Free (at shipping)
----------
aa=17.4mm bb=(7.5)mm cc=275r/min
----------
a=38.5deg+-5deg b=(27deg) c=17deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400+-5r/min Ra=9.2mm
----------

0000001601 RACK SENSOR

Test data 101603-6800
R:Rack position (mm) V:Voltage (V) After installing the rack sensor, confirm the output value (VR).
----------
N1=800r/min Ra=R1(12.1)mm VR=1.99+-0.01V
----------

Timing setting

Test data 101603-6800
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(0deg)




Have questions with 101603-6800?





Group cross 101603-6800 ZEXEL

Mitsubishi 

101603-6800  
 
ME035799 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 145 
ME076006 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 146 
ME056585 
INJECTION-PUMP ASSEMBLY
6D22
 
ME056583 
INJECTION-PUMP ASSEMBLY
6D22
 
ME035344 
INJECTION-PUMP ASSEMBLY
6D14
 
ME035345 
INJECTION-PUMP ASSEMBLY
6D14
9 400 610 652 
ME035346 
INJECTION-PUMP ASSEMBLY
6D14
F 019 Z10 238 
ME035347 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035348 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035349 
INJECTION-PUMP ASSEMBLY
6D15
Back to top