101603-6170 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016036170 me035584


101603-6170 INJECTION-PUMP ASSEMBLY
Rating:
31
Buy INJECTION-PUMP ASSEMBLY 101603-6170 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-6170 1016036170
MITSUBISHI ME035584 me035584

Cross reference number

ZEXEL 101603-6170 1016036170
MITSUBISHI ME035584 me035584


Zexel num
Bosch num
Firm num
Name
101603-6170 
 
ME035584  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D15 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   60 58.1 61.9
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   10+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   10 8.9 11.1
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   60 59 61
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.4
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   76.5 72.5 80.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   70 30 110
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1350
Advance angle deg.   2.4 1.9 2.9
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-6170
N:Pump speed R:Rack position (mm) (1)Excess fuel setting for starting: SXL (2)Damper spring setting (3)Rack difference between N = N1 and N = N2
----------
SXL=R1(11)+2+1.8mm N1=1450r/min N2=600r/min
----------

Speed control lever angle

Test data 101603-6170
F:Full speed
----------

----------
a=13deg+-5deg

0000000901

Test data 101603-6170
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=20.5deg+-3deg b=30deg+-5deg

Stop lever angle

Test data 101603-6170
N:Engine manufacturer's normal use S:Stop the pump. (1)Rack position = aa (2)Rack position bb (3)Free (at shipping)
----------
aa=7-0.5mm bb=13.5mm
----------
a=55.5deg+7deg-5deg b=21.5deg+-5deg c=(1deg)

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400+-5r/min Ra=9.2mm
----------

Timing setting

Test data 101603-6170
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(1deg)




Have questions with 101603-6170?





Group cross 101603-6170 ZEXEL

Mitsubishi 

 
ME035638 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 111 
ME047085 
INJECTION-PUMP ASSEMBLY
6D16CT
 
 
INJECTION-PUMP ASSEMBLY
6D16WT
9 400 615 112 
ME047098 
INJECTION-PUMP ASSEMBLY
6D16WT
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME035643 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035625 
INJECTION-PUMP ASSEMBLY
6D15
9 400 615 113 
ME032909 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035636 
INJECTION-PUMP ASSEMBLY
6D15
101603-6170  
 
ME035584 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 114 
ME035641 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME035583 
INJECTION-PUMP ASSEMBLY
6D14