101603-6131 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016036131


101603-6131 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 101603-6131 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-6131 1016036131

Cross reference number

ZEXEL 101603-6131 1016036131


Zexel num
Bosch num
Firm num
Name
101603-6131 
101603-6132 
 
  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3 2.95 3.05
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.1
Pump speed r/min   800 800 800
Each cylinder's injection qty mm3/st.   88 85.4 90.6
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   10.5 9 12
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.1)
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   88 87 89
Basic   *
Fixing the lever   *
Boost pressure kPa   61.3 61.3
Boost pressure mmHg   460 460
Injection quantity adjustment_04
Adjusting point   C
Rack position   (R1-0.8)
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   67 65 69
Fixing the lever   *
Boost pressure kPa   28 28 28
Boost pressure mmHg   210 210 210
Injection quantity adjustment_05
Adjusting point   I
Rack position   13.9+-0. 5
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   90 70 110
Fixing the lever   *
Rack limit   *
Boost compensator adjustment
Pump speed r/min   700 700 700
Rack position   R1-1.1
Boost pressure kPa   22 22 22
Boost pressure mmHg   165 165 165
Boost compensator adjustment_02
Pump speed r/min   700 700 700
Rack position   (R1-0.8)
Boost pressure kPa   28 26.7 29.3
Boost pressure mmHg   210 200 220
Boost compensator adjustment_03
Pump speed r/min   700 700 700
Rack position   R1(12.1)
Boost pressure kPa   48 41.3 54.7
Boost pressure mmHg   360 310 410
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1300
Advance angle deg.   1.6 1.1 2.1
Timer adjustment_04
Pump speed r/min   1400
Advance angle deg.   3.5 3 4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-6131
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT (3)Boost compensator stroke: BCL
----------
T1=B44 BCL=1.1+-0.1mm
----------

Speed control lever angle

Test data 101603-6131
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=(41deg)+-3deg

Stop lever angle

Test data 101603-6131
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at speed = rated point and rack position = aa and confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed = cc. Rack position = bb. (3)Rack position = approximately dd (4)Free (at shipping)
----------
aa=(7.5)mm bb=(9)mm cc=275r/min dd=17.4mm
----------
a=38.5deg+-5deg b=(27deg) c=17deg+-5deg

0000001201

Test data 101603-6131
I:Idle F:At operation, hold it in the full speed position. (1)Rack position = aa, speed = bb.
----------
aa=8.4mm bb=1490r/min
----------
a=15deg+-5deg b=36deg+-3deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400+-5r/min Ra=9.2mm
----------

Timing setting

Test data 101603-6131
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=16deg
----------
a=(1deg)




Have questions with 101603-6131?





Group cross 101603-6131 ZEXEL

Mitsubishi 

 
ME035638 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 111 
ME047085 
INJECTION-PUMP ASSEMBLY
6D16CT
 
 
INJECTION-PUMP ASSEMBLY
6D16WT
9 400 615 112 
ME047098 
INJECTION-PUMP ASSEMBLY
6D16WT
 
 
INJECTION-PUMP ASSEMBLY
6D14T
101603-6131  

101603-6132 
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME035643 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035625 
INJECTION-PUMP ASSEMBLY
6D15
9 400 615 113 
ME032909 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035636 
INJECTION-PUMP ASSEMBLY
6D15
 
ME035584 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 114 
ME035641 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME035583 
INJECTION-PUMP ASSEMBLY
6D14
Back to top