101603-1600 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016031600 me056250


101603-1600 INJECTION-PUMP ASSEMBLY
Rating:
47
Buy INJECTION-PUMP ASSEMBLY 101603-1600 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-1600 1016031600
MITSUBISHI ME056250 me056250

Service parts 101603-1600 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-2421
3. GOVERNOR 105490-4230
4. SUPPLY PUMP 105210-4151
5. AUTOM. ADVANCE MECHANIS 105614-4100
6. COUPLING PLATE 105662-0590
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4771
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 21.6(220)
13. NOZZLE-HOLDER 105031-3522
14. NOZZLE 105015-4380
15. NOZZLE SET

Include in #1:

101603-1600 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101603-1600 1016031600
MITSUBISHI ME056250 me056250


Zexel num
Bosch num
Firm num
Name
101603-1600 
 
ME056250  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D22 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.5 4.45 4.55
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   9.4
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   107 103.6 110.4
Basic   *
Fixing the rack   *
Injection quantity adjustment_02
Adjusting point   C
Rack position   8+-0.5
Pump speed r/min   200 200 200
Each cylinder's injection qty mm3/st.   18.5 15.7 21.3
Fixing the rack   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(9.4)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   107 106 108
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(9.4)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   108.5 106 111
Difference in delivery mm3/st.   9 9 9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   137 117 157
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   800
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   900
Advance angle deg.   0.9 0.4 1.4
Timer adjustment_03
Pump speed r/min   1150
Advance angle deg.   3 2.5 3.5
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   4 4 5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101603-1600
N:Pump speed R:Rack position (mm) (1)Beginning of damper spring operation: DL (2)Excess fuel setting for starting: SXL
----------
DL=6-0.2mm SXL=R1(9.4)+0.2mm
----------

Speed control lever angle

Test data 101603-1600
F:Full speed
----------

----------
a=10deg+-5deg

0000000901

Test data 101603-1600
F:Full load I:Idle
----------

----------
a=21.5deg+-5deg b=28.5deg+-3deg

Stop lever angle

Test data 101603-1600
N:Pump normal S:Stop the pump.
----------

----------
a=(54deg) b=(71deg)

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325+-5r/min Ra=7.3mm
----------




Have questions with 101603-1600?





Group cross 101603-1600 ZEXEL

Mitsubishi 

101603-1600  
 
ME056250 
INJECTION-PUMP ASSEMBLY
6D22
 
ME056251 
INJECTION-PUMP ASSEMBLY
6D22
 
ME039283 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 020 
ME035872 
INJECTION-PUMP ASSEMBLY
6D14
 
ME035876 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME035874 
INJECTION-PUMP ASSEMBLY
6D14T

M.Bishi-Hi.-Nag 

 
EZ40071 
INJECTION-PUMP ASSEMBLY
6AAC
 
EZ40075 
INJECTION-PUMP ASSEMBLY
6AAC
 
EZ40089 
INJECTION-PUMP ASSEMBLY
6AAC

Mitsubishi 

 
ME035733 
INJECTION-PUMP ASSEMBLY
6D14

M.Bishi-Hi.-Nag 

 
EZ40077 
INJECTION-PUMP ASSEMBLY
6AAC
Back to top