101603-0850 ZEXEL 9 400 615 006 BOSCH INJECTION-PUMP ASSEMBLY 9400615006 1016030850 1156018730


101603-0850 INJECTION-PUMP ASSEMBLY
Rating:
59
Buy INJECTION-PUMP ASSEMBLY 101603-0850 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 615 006 9400615006
ZEXEL 101603-0850 1016030850
ISUZU 1156018730 1156018730

Include in #1:

Cross reference number

BOSCH 9 400 615 006 9400615006
ZEXEL 101603-0850 1016030850
ISUZU 1156018730 1156018730


Zexel num
Bosch num
Firm num
Name
101603-0850 
9 400 615 006 
1156018730  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1 K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Rack position
Point A
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.7
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   52.5 50.9 54.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.8+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   9.4 8.1 10.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.7)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   52.5 51.5 53.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.3
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   59 55.8 62.2
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.15
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   58.3 55.1 61.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   15.3+-0. 5
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   80 80 85
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1100--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1050
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1300
Advance angle deg.   1.2 0.7 1.7
Timer adjustment_04
Pump speed r/min   1600
Advance angle deg.   3 2.5 3.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-0850
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=97
----------

Speed control lever angle

Test data 101603-0850
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=34deg+-5deg b=43deg+-3deg

Stop lever angle

Test data 101603-0850
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

Timing setting

Test data 101603-0850
(1)Pump vertical direction (2)Position of timer's threaded hole at the No. 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=9deg
----------
a=(60deg)




Have questions with 101603-0850?





Group cross 101603-0850 ZEXEL

Isuzu 

 
1156018800 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018801 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018802 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018803 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018411 
INJECTION-PUMP ASSEMBLY
6QA2
 
1156018421 
INJECTION-PUMP ASSEMBLY
6QA2
 
1156018422 
INJECTION-PUMP ASSEMBLY
6QA2
 
1156018710 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156018720 
INJECTION-PUMP ASSEMBLY
6BD1T
101603-0850  
9 400 615 006 
1156018730 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156018740 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156015762 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156015764 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156019820 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156019821 
INJECTION-PUMP ASSEMBLY
6SA1
9 400 615 007 
1156019822 
INJECTION-PUMP ASSEMBLY
6SA1
Back to top