101603-0681 ZEXEL 9 400 613 088 BOSCH INJECTION-PUMP ASSEMBLY 9400613088 1016030681 1156016165


101603-0681 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 101603-0681 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 613 088 9400613088
ZEXEL 101603-0681 1016030681
ISUZU 1156016165 1156016165

Service parts 101603-0681 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-4870
3. GOVERNOR 105931-6940
4. SUPPLY PUMP 105220-5920
5. AUTOM. ADVANCE MECHANIS 105614-3201
6. COUPLING PLATE 105661-0661
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4823
11. Nozzle and Holder 1-15300-104-2
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105030-3201
14. NOZZLE 105015-4130
15. NOZZLE SET

Include in #1:

101603-0681 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 613 088 9400613088
ZEXEL 101603-0681 1016030681
ISUZU 1156016165 1156016165


Zexel num
Bosch num
Firm num
Name
101603-0681 
9 400 613 088 
1156016165  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 K 14BE INJECTION PUMP ASSY PE6A PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.4
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   70.7 69.1 72.3
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.6+-0.5
Pump speed r/min   260 260 260
Average injection quantity mm3/st.   9.4 8.1 10.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.4)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   70.7 69.7 71.7
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   (R1-0.4)
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   76 74.4 77.6
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   86 86 96
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   550--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   500
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1500
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-0681
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=E60
----------

Speed control lever angle

Test data 101603-0681
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=42deg+-5deg b=35deg+-3deg

Stop lever angle

Test data 101603-0681
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101603-0681
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=900r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(11.4)mm Rb=R1-0.7mm Pa=89.8+-2.7kPa(674+-20mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=70.7+-1cm3/1000st Q2=(59.1)+-1.6cm3/1000st

Timing setting

Test data 101603-0681
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(60deg)




Have questions with 101603-0681?





Group cross 101603-0681 ZEXEL

Isuzu 

 
1156016213 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016223 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016231 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016234 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 615 005 
1156016236 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016241 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016244 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016251 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016254 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016033 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016163 
INJECTION-PUMP ASSEMBLY
6BG1
101603-0681  
9 400 613 088 
1156016165 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016171 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016174 
INJECTION-PUMP ASSEMBLY
6BG1
Back to top