101603-0540 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016030540 1156014391


101603-0540 INJECTION-PUMP ASSEMBLY
Rating:
9
Buy INJECTION-PUMP ASSEMBLY 101603-0540 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-0540 1016030540
ISUZU 1156014391 1156014391

Service parts 101603-0540 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-0570
3. GOVERNOR 105931-3030
4. SUPPLY PUMP 105220-4561
5. AUTOM. ADVANCE MECHANIS 105612-3270
6. COUPLING PLATE 105661-0681
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-4582
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 18.1(185)
13. NOZZLE-HOLDER 105031-3952
14. NOZZLE 105015-4130
15. NOZZLE SET

Include in #1:

101603-0540 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101603-0540 1016030540
ISUZU 1156014391 1156014391


Zexel num
Bosch num
Firm num
Name
101603-0540 
101603-4450 
 
1156014391  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.3
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   48.9 47.3 50.5
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   8.7 7.4 10
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.3)
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   48.9 47.9 49.9
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.35
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   54.3 51.1 57.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 60 65
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   350--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   300
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   900
Advance angle deg.   2 1.5 2.5
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-0540
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=B08
----------

Speed control lever angle

Test data 101603-0540
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=37deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101603-0540
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=37deg+-5deg b=40deg+-3deg

0000001501 TAMPER PROOF

Test data 101603-0540
Tamper proof adjustment (1)Set the full load screw at rack position Ra+0.4. (2)Set the full load position Ra using screw (A).
----------
Ra=R1(10.3)mm
----------

Timing setting

Test data 101603-0540
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(60deg)




Have questions with 101603-0540?





Group cross 101603-0540 ZEXEL

Isuzu 

 
1156018010 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018011 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018012 
INJECTION-PUMP ASSEMBLY
6SA1
9 400 615 003 
1156018013 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017840 
INJECTION-PUMP ASSEMBLY
6SA1
9 400 615 004 
1156017841 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017850 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017851 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017751 
INJECTION-PUMP ASSEMBLY
6BG1TC
101603-0540  

101603-4450 
 
1156014391 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156018070 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156018080 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156017891 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018131 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156018530 
INJECTION-PUMP ASSEMBLY
6BD1T
Back to top