101601-7740 ZEXEL 9 400 614 661 BOSCH INJECTION-PUMP ASSEMBLY 9400614661 1016017740 1156013811


101601-7740 INJECTION-PUMP ASSEMBLY
Rating:
55
Buy INJECTION-PUMP ASSEMBLY 101601-7740 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 614 661 9400614661
ZEXEL 101601-7740 1016017740
ISUZU 1156013811 1156013811

Include in #1:

Cross reference number

BOSCH 9 400 614 661 9400614661
ZEXEL 101601-7740 1016017740
ISUZU 1156013811 1156013811


Zexel num
Bosch num
Firm num
Name
101601-7740 
9 400 614 661 
1156013811  ISUZU
INJECTION-PUMP ASSEMBLY
6QA1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-0220
Overflow valve opening pressure kPa   147 113 181
Overflow valve opening pressure kgf/cm2   1.5 1.15 1.85
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.7 3.65 3.75
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.5 60.5
Difference between angles 2
Cyl.1-2
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cal 1-3
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-5
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   11.2
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   111.5 109.5 113.5
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   11.6
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   115 114 116
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   8.6+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   11.5 9.2 13.8
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Injection quantity adjustment_04
Adjusting point   D
Rack position   -
Pump speed r/min   150 150 150
Each cylinder's injection qty mm3/st.   140 140
Fixing the lever   *
Remarks
Startup boost setting
 
Injection quantity adjustment_05
Adjusting point   E
Rack position   10.2
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   80.5 79.5 81.5
Max. variation between cylinders %   0 -2 2
Fixing the lever   *
Remarks
At absolute pressure 61.3 kPa {460 mmHg}
 
Timer adjustment
Pump speed r/min   500
Advance angle deg.   0.3
Timer adjustment_02
Pump speed r/min   600
Advance angle deg.   0.8 0.1 0.8
Timer adjustment_03
Pump speed r/min   700
Advance angle deg.   0.8 0.3 1.3
Timer adjustment_04
Pump speed r/min   900
Advance angle deg.   2 1.5 2.5
Timer adjustment_05
Pump speed r/min   1150
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-7740
N:Pump speed R:Rack position (mm) (1)Beginning of damper spring operation: DL (2)Excess fuel setting for starting: SXL (3)Aneroid compensator absolute pressure: P1
----------
DL=6.5+-0.5mm SXL=12.4+-0.1mm P1=61.3+-0.7kPa(460+-5mmHg)
----------

Speed control lever angle

Test data 101601-7740
F:Full speed M:Minimum-maximum speed (1)Set the pump speed at aa. (At delivery) (2)Set the speed at bb. Set using two nuts.
----------
aa=1150r/min bb=550r/min
----------
a=3deg+-5deg b=11deg+-5deg

0000000901

Test data 101601-7740
F:Full load I:Idle (1)Stopper bolt setting (2)Attach the return spring to the upper hole and adjust the governor.
----------

----------
a=4deg+-5deg b=22deg+-3deg

Stop lever angle

Test data 101601-7740
N:Pump normal S:Stop the pump.
----------

----------
a=35.5deg+-5deg b=71deg+-5deg

0000001501 ACS

Test data 101601-7740
(A) Set screw (B) Push rod 1 1. Aneroid compensator unit adjustment (1)Screw in (A) to obtain L1. 2. Adjustment following governor installation (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above.
----------
N1=700r/min L1=(0.6~0.9)mm
----------
R1=11.6mm R2=10.2mm P1=(90.6)kPa((680)mmHg) P2=61.3+-0.7kPa(460+-5mmHg) Q1=115+-1cm3/1000st Q2=80.5+-1cm3/1000st




Have questions with 101601-7740?





Group cross 101601-7740 ZEXEL

Isuzu 

 
1156012481 
INJECTION-PUMP ASSEMBLY
6BF1
 
1156012491 
INJECTION-PUMP ASSEMBLY
6BF1
 
1156012501 
INJECTION-PUMP ASSEMBLY
6BF1
 
1156012930 
INJECTION-PUMP ASSEMBLY
6BD1
101601-7740  
9 400 614 661 
1156013811 
INJECTION-PUMP ASSEMBLY
6QA1
9 400 614 662 
1156013820 
INJECTION-PUMP ASSEMBLY
6BB1
 
1156013100 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013101 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013102 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013103 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013120 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013121 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013122 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 614 663 
1156013123 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013124 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013500 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156012820 
INJECTION-PUMP ASSEMBLY
6BG1
 
 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156012821 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156012822 
INJECTION-PUMP ASSEMBLY
6BG1
Back to top