Rating:
Information injection-pump assembly
BOSCH
9 400 614 204
9400614204
ZEXEL
101481-0190
1014810190
ISUZU
8970892601
8970892601
Service parts 101481-0190 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
8-97025-466-0
12.
Open Pre:MPa(Kqf/cm2)
13.2{135}
15.
NOZZLE SET
Cross reference number
BOSCH
9 400 614 204
9400614204
ZEXEL
101481-0190
1014810190
ISUZU
8970892601
8970892601
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-4920
Overflow valve opening pressure
kPa
127
107
147
Overflow valve opening pressure
kgf/cm2
1.3
1.1
1.5
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
2.8
2.75
2.85
Rack position
Point A R=A
Point A R=A
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
-
Rack position
12
Pump speed
r/min
950
950
950
Average injection quantity
mm3/st.
79.5
77.9
81.1
Max. variation between cylinders
%
0
-4
4
Basic
*
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_02
Adjusting point
H
Rack position
9.5+-0.5
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
13
11.7
14.3
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_03
Adjusting point
A
Rack position
R1(12)
Pump speed
r/min
950
950
950
Average injection quantity
mm3/st.
79.5
78.5
80.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_04
Adjusting point
B
Rack position
R1-0.1
Pump speed
r/min
1375
1375
1375
Average injection quantity
mm3/st.
81
77
85
Fixing the lever
*
Injection quantity adjustment_05
Adjusting point
C
Rack position
R1-0.25
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
66
62
70
Fixing the lever
*
Injection quantity adjustment_06
Adjusting point
I
Rack position
-
Pump speed
r/min
150
150
150
Average injection quantity
mm3/st.
93
93
109
Fixing the lever
*
Timer adjustment
Pump speed
r/min
550--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
500
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1500
Advance angle
deg.
2.5
2
3
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Torque cam stamping: T1
(2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=J13
----------
----------
T1=J13
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Stopper bolt setting
(2)At M/S adjustment, confirm that M/S turns ON when speed lever is returned from full to idle and gap between speed lever and idle side stopper bolt is aa. Confirm that M/S turns OFF when speed lever is again returned from full to idle at gap bb.
----------
aa=0.1mm bb=0.25mm
----------
a=7.5deg+-5deg b=33deg+-3deg
----------
aa=0.1mm bb=0.25mm
----------
a=7.5deg+-5deg b=33deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=45deg+-5deg b=29deg+-5deg
----------
----------
a=45deg+-5deg b=29deg+-5deg
0000001501 ACS
(A) Set screw
(B) Push rod 1
(C) Push rod 2
(D) Cover
1. Aneroid compensator unit adjustment
(1)Select the push rod 2 to obtain L2.
(2)Screw in (A) to obtain L1.
2. Adjustment when mounting the governor.
(1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position.
(2)Screw in the aneroid compensator to obtain the performance shown in the graph above.
(3)As there is hysterisis, measure when the absolute pressure drops.
(4)Hysterisis must not exceed rack position = h1.
----------
N1=950r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(12)mm Rb=R1-0.25mm Pa=74.6+-2.7kPa(560+-20mmHg) Pb=61.6+-0.7kPa(462+-5mmHg) Q1=79.5+-1cm3/1000st Q2=(74)+-2cm3/1000st
----------
N1=950r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(12)mm Rb=R1-0.25mm Pa=74.6+-2.7kPa(560+-20mmHg) Pb=61.6+-0.7kPa(462+-5mmHg) Q1=79.5+-1cm3/1000st Q2=(74)+-2cm3/1000st
0000001601 FICD
Nut A
(B) Screw
Negative pressure port C
1. FICD adjustment
(1)Loosen nut A and screw in screw B.
(2)Apply negative pressure P1 to C, turn screw B slowly and tighten nut A at N1 and R1.
(3)Nut A tightening torque T1
(4)Apply negative pressure P2 to C several times and confirm that the FICD operates normally.
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) N1=450r/min R1=9.3+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L1=3+1mm
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) N1=450r/min R1=9.3+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L1=3+1mm
Timing setting
(1)Pump vertical direction
(2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=10deg
----------
a=(100deg)
----------
aa=10deg
----------
a=(100deg)