101481-0152 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014810152 8970106482


101481-0152 INJECTION-PUMP ASSEMBLY
Rating:
8
Buy INJECTION-PUMP ASSEMBLY 101481-0152 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101481-0152 1014810152
ISUZU 8970106482 8970106482

Cross reference number

ZEXEL 101481-0152 1014810152
ISUZU 8970106482 8970106482


Zexel num
Bosch num
Firm num
Name
101481-0152 
101481-0153 
 
8970106482  ISUZU
INJECTION-PUMP ASSEMBLY
4BD2 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   2.8 2.75 2.85
Rack position
Point A
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.1
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   76.8 75.2 78.4
Max. variation between cylinders %   0 -4 4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   365 365 365
Average injection quantity mm3/st.   9 7.7 10.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.1)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   76.8 75.8 77.8
Basic   *
Fixing the lever   *
Boost pressure kPa   24 24
Boost pressure mmHg   180 180
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.5
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   72.4 68.4 76.4
Fixing the lever   *
Boost pressure kPa   24 24
Boost pressure mmHg   180 180
Injection quantity adjustment_05
Adjusting point   C
Rack position   R2(R1-0. 15)
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   67.5 63.5 71.5
Fixing the lever   *
Boost pressure kPa   24 24
Boost pressure mmHg   180 180
Injection quantity adjustment_06
Adjusting point   D
Rack position   R2-0.3
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   60.8 56.8 64.8
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   93 93 109
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   650 650 650
Rack position   R2-0.3
Boost pressure kPa   6.7 6.7 9.4
Boost pressure mmHg   50 50 70
Boost compensator adjustment_02
Pump speed r/min   650 650 650
Rack position   R2(R1-0. 15)
Boost pressure kPa   10.7 10.7 10.7
Boost pressure mmHg   80 80 80
Timer adjustment
Pump speed r/min   550--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   500
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1500
Advance angle deg.   3.9 3.4 4.4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101481-0152
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL
----------
T1=F86 BCL=0.3+-0.1mm
----------

Speed control lever angle

Test data 101481-0152
F:Full speed I:Idle (1)Stopper bolt setting (2)At M/S adjustment, confirm that M/S turns ON when speed lever is returned from full to idle and gap between speed lever and idle side stopper bolt is aa. Confirm that M/S turns OFF when speed lever is again returned from full to idle at gap bb.
----------
aa=0.1mm bb=0.25mm
----------
a=6.5deg+-5deg b=32deg+-3deg

Stop lever angle

Test data 101481-0152
N:Pump normal S:Stop the pump.
----------

----------
a=45deg+-5deg b=29deg+-5deg

0000001501 ACS

Test data 101481-0152
(A) Aneroid compensator (B) Set screw (C) Boost pressure inlet (D) Rack positioning screw (E): Aneroid compensator main body (F) Boost compensator spring (G): Aneroid compensator spring (H): Adjusting notch (I) Push rod 1. Instructions for adjusting the boost compensator with the aneroid compensator (1)Select a pushrod to obtain L1 at full boost. (2)Remove the aneroid compensator main body. (3)Adjust the booster compensator stroke by turning the screw at (D. (4)Adjust the beginning of boost compensator operation by turning the notch at (H). (5)Install the aneroid compensator at full boost state. (6)Turn (B)'s set screw so that the distance between the snapring and the body is L2. (7)Screw in the aneroid compensator main body and adjust the point where it comes into play.
----------
L1=24+-0.5mm L2=1.5+-0.5mm
----------

0000001601 ACS

Test data 101481-0152
(A) Set screw (B) Push rod 1 (C) Push rod 2 1. Adjustment of the aneroid compensator itself and the adjustment after mounting the governor (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in (A) to obtain the performance shown in the graph (to obtain L1). (3)Adjust the (D) spacer so that dimension L2 is obtained. (4)As there is hysterisis, measure when the absolute pressure drops. (5)Hysterisis must not exceed rack position = h1.
----------
N1=950r/min L1=1.5+-0.5mm L2=24+-0.5mm h1=0.15mm
----------
Ra=R1(12.1)mm Rb=R1-0.25mm P1=74.6+-2.7kPa(560+-20mmHg) P2=61.6+-0.7kPa(462+-5mmHg) Q1=76.8+-1cm3/1000st Q2=(70.7)+-2cm3/1000st

0000001701 FICD

Test data 101481-0152
(a) actuator (B) Screw (c) Nut 1. FICD adjustment (1)Set the clearance between the actuator rod and speed lever to approx. L1. (2)Loosen nut (C) and fully screw in the actuator (A)'s screw (B). (3)Apply negative pressure P1 to the actuator (A) and fully screw in screw (B). (4)Set the pump speed at N1 (5)Set the rack position at R1. (6)Tighten the actuator (A)'s screw (B) and fix using the nut (C). (7)Apply P2 to negative pressure port A and confirm that the FICD operates normally.
----------
L1=(3)mm P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) N1=450r/min R1=9.3+-0.1mm
----------

Timing setting

Test data 101481-0152
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=8deg
----------
a=(100deg)




Have questions with 101481-0152?





Group cross 101481-0152 ZEXEL

Isuzu 

 
8970106480 
INJECTION-PUMP ASSEMBLY
4BD2
 
8970106481 
INJECTION-PUMP ASSEMBLY
4BD2
101481-0152  

101481-0153 
 
8970106482 
INJECTION-PUMP ASSEMBLY
4BD2
 
8970106483 
INJECTION-PUMP ASSEMBLY
4BD2
9 400 611 742 
8970106485 
INJECTION-PUMP ASSEMBLY
4BD2
9 400 611 742 
8970106484 
INJECTION-PUMP ASSEMBLY
4BD2
Back to top