Rating:
Information injection-pump assembly
ZEXEL
101402-2340
1014022340
Cross reference number
ZEXEL
101402-2340
1014022340
Zexel num
Bosch num
Firm num
Name
101402-2340
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-5720
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
3.1
3.05
3.15
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
7.6
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
48
46
50
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
8.2
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
58
55
61
Max. variation between cylinders
%
0
-4
4
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
7+-0.5
Pump speed
r/min
360
360
360
Average injection quantity
mm3/st.
10.1
8.6
11.6
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Injection quantity adjustment_04
Adjusting point
D
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
97
97
107
Fixing the lever
*
Rack limit
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT
(4)Set idle sub-spring
(5)Rack difference between N = N1 and N = N2
----------
K=12 N1=750r/min N2=300r/min
----------
----------
K=12 N1=750r/min N2=300r/min
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Set the speed at aa, set the stopper bolt
(2)When pump speed set at bb
(3)Stopper bolt setting
----------
aa=900r/min bb=755r/min
----------
a=3deg+-5deg b=19deg+-5deg c=6deg+-5deg
----------
aa=900r/min bb=755r/min
----------
a=3deg+-5deg b=19deg+-5deg c=6deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)At delivery
(2)Rack position aa or less, pump speed bb
----------
aa=6.5mm bb=0r/min
----------
a=27deg+-5deg b=53deg+-5deg
----------
aa=6.5mm bb=0r/min
----------
a=27deg+-5deg b=53deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(70deg)
----------
----------
a=(70deg)
Have questions with 101402-2340?
Group cross 101402-2340 ZEXEL
Hino
Hino
Hino
101402-2340
INJECTION-PUMP ASSEMBLY