101401-7460 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014017460


101401-7460 INJECTION-PUMP ASSEMBLY
Rating:
63
Buy INJECTION-PUMP ASSEMBLY 101401-7460 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-7460 1014017460

Service parts 101401-7460 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101041-8480
3. GOVERNOR 105932-2721
4. SUPPLY PUMP 105210-6100
5. AUTOM. ADVANCE MECHANIS 105676-5120
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-6051
11. Nozzle and Holder 8-97119-812-0
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105048-3673
14. NOZZLE 105017-1860
15. NOZZLE SET

Include in #1:

101401-7460 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101401-7460 1014017460


Zexel num
Bosch num
Firm num
Name
101401-7460 
 
   
INJECTION-PUMP ASSEMBLY
14BC PE4A,5A, PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-4-2
Pre-stroke mm   4.1 4.05 4.15
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.3
Pump speed r/min   960 960 960
Average injection quantity mm3/st.   68.5 66.9 70.1
Max. variation between cylinders %   0 -4 4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H'
Rack position   9.7+-0.5
Pump speed r/min   310 310 310
Average injection quantity mm3/st.   11.5 10.2 12.8
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   H
Rack position   9.6+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   10.5 9.2 11.8
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   A
Rack position   R1(11.3)
Pump speed r/min   960 960 960
Average injection quantity mm3/st.   68.5 67.5 69.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   B
Rack position   R1-0.05
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   78.5 74.5 82.5
Fixing the lever   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-7460
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=N58
----------

Speed control lever angle

Test data 101401-7460
F:Full speed I:Idle (1)Stopper bolt set position 'H' (rack position = aa, speed = bb)
----------
aa=(9.6)mm bb=325r/min
----------
a=41deg+-5deg b=39deg+-3deg

Stop lever angle

Test data 101401-7460
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=64mm
----------
a=20deg+-5deg b=29deg+-5deg

0000001501 RACK SENSOR

Test data 101401-7460
Rack sensor adjustment 1. Flange type rack sensor (rack sensor adjustment -5*20) (1)These types of rack sensors do not need adjustment. Confirm the performance with the following procedures. (2)Mount the rack sensor main body to the pump main body. (3)Fix the pump lever at full. (4)At supply voltage V1, pump speed N1 and rack position Ra, confirm that the amp's output voltage is Vist. (5)Move the pump lever two or three times. (6)Set again to full. (7)Confirm that the amplifier output voltage is Vist. (8)Fix the caution plate to the upper part of the rack sensor. (For those without the caution plate instructions, make sure the nameplate of the rack sensor carries the "Don't hold here" caution.) (9)Apply red paint to the rack sensor mounting bolts (2 places).
----------
V1=5+-0.01V N1=960r/min Ra=R1(11.3)mm Vist=2.4+-0.28V
----------

0000001601 FICD

Test data 101401-7460
(A) applied negative pressure (B) Screw (c) Nut 1. Set the actuator as described below. (1)Confirm that there is clearance between the actuator lever and the speed lever. (2)Loosen the nut (C). (3)Push in the screw (B). (4)Apply P1 from the actuator (A) part. (5)Pull out the screw (B) slowly. (6)Tighten and fix the nut (C) when pump speed is Na and the rack position is Ra. (7)Torque the nut (C) to T1. (8)Apply P2 several times. (9)Confirm that the actuator functions normally. (10)Confirm that there is a clearance between the actuator lever and the speed lever at that time.
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) Na=410r/min Ra=9.4+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L=(5)mm

Timing setting

Test data 101401-7460
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)Stamping position on the A/T outer rim (4)Pump bracket check hole position. (5)At the No 1 cylinder's beginning of injection, align with the projection seen through the bracket's check hole and mark the A/T's bevel C1. (6)B.T.D.C.: aa
----------
aa=7deg
----------
a=(60deg) b=(85deg)




Have questions with 101401-7460?





Group cross 101401-7460 ZEXEL

F 019 Z10 158 
 
INJECTION-PUMP ASSEMBLY
9 400 610 423 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 759 
8971449930 
INJECTION-PUMP ASSEMBLY
4HJ1
9 400 619 979 
8971705060 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 760 
8971705061 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971705070 
INJECTION-PUMP ASSEMBLY
4HE1-T
9 400 611 145 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 761 
8971705071 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 762 
8971705040 
INJECTION-PUMP ASSEMBLY
4HG1
9 400 610 424 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 763 
8971705050 
INJECTION-PUMP ASSEMBLY
4HG1
 
8971784850 
INJECTION-PUMP ASSEMBLY
4HG1-T
 
8971784852 
INJECTION-PUMP ASSEMBLY
4HG1-T
F 019 Z20 414 
8971784853 
INJECTION-PUMP ASSEMBLY
4HG1-T
9 400 612 026 
8971784854 
INJECTION-PUMP ASSEMBLY
4HG1-T
9 400 612 910 
8971784855 
INJECTION-PUMP ASSEMBLY
4HG1-T
101401-7460  
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 764 
8972041000 
INJECTION-PUMP ASSEMBLY
4HF1
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 765 
8972041010 
INJECTION-PUMP ASSEMBLY
4HG1
9 400 613 766 
8972033690 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 767 
8972033700 
INJECTION-PUMP ASSEMBLY
4HF1