101401-4680 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014014680 8971006570


101401-4680 INJECTION-PUMP ASSEMBLY
Rating:
18
Buy INJECTION-PUMP ASSEMBLY 101401-4680 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-4680 1014014680
ISUZU 8971006570 8971006570

Service parts 101401-4680 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101041-8100
3. GOVERNOR 105931-9230
4. SUPPLY PUMP 105210-5270
5. AUTOM. ADVANCE MECHANIS 105676-5010
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5253
11. Nozzle and Holder 8-97114-015-0
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105048-3673
14. NOZZLE 105017-1210
15. NOZZLE SET

Include in #1:

101401-4680 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101401-4680 1014014680
ISUZU 8971006570 8971006570


Zexel num
Bosch num
Firm num
Name
101401-4680 
101401-4681 
 
8971006570  ISUZU
INJECTION-PUMP ASSEMBLY
4HF1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-3920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-4-2
Pre-stroke mm   4.1 4.05 4.15
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12
Pump speed r/min   960 960 960
Average injection quantity mm3/st.   51.5 49.9 53.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   285 285 285
Average injection quantity mm3/st.   8.5 7.2 9.8
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12)
Pump speed r/min   960 960 960
Average injection quantity mm3/st.   51.5 50.5 52.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.6
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   79 75 83
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   79 79 111
Fixing the lever   *
Timer adjustment
Pump speed r/min   -
Advance angle deg.   0 0 0
Remarks
Measure speed (beginning of operation).
 
Timer adjustment_02
Pump speed r/min   -
Advance angle deg.   5 4.5 5.5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101401-4680
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=G97
----------

Speed control lever angle

Test data 101401-4680
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=43deg+-5deg b=37deg+-3deg

Stop lever angle

Test data 101401-4680
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=64mm
----------
a=20deg+-5deg b=29deg+-5deg

0000001501 FICD

Test data 101401-4680
(A) applied negative pressure (B) Screw (c) Nut 1. Set the actuator as described below. (1)Confirm that there is clearance between the actuator lever and the speed lever. (2)Loosen the nut (C). (3)Push in the screw (B). (4)Apply P1 from the actuator (A) part. (5)Pull out the screw (B) slowly. (6)Tighten and fix the nut (C) when pump speed is Na and the rack position is Ra. (7)Torque the nut (C) to T1. (8)Apply P2 several times. (9)Confirm that the actuator functions normally. (10)Confirm that there is a clearance between the actuator lever and the speed lever at that time.
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) Na=440r/min Ra=9.55+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L=(2)mm

Timing setting

Test data 101401-4680
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)Stamping position on the A/T outer rim (4)Pump bracket check hole position. (5)At the No 1 cylinder's beginning of injection, align with the projection seen through the bracket's check hole and mark the A/T's bevel C1. (6)B.T.D.C.: aa
----------
aa=11deg
----------
a=(60deg) b=(85deg)




Have questions with 101401-4680?





Group cross 101401-4680 ZEXEL

Isuzu 

 
8970903560 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903580 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 099 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 715 
8970903581 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903590 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 716 
8970903591 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 100 
8970903600 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 317 
8970903610 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 318 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 717 
8970903611 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 319 
8970903571 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 320 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 613 718 
8970903572 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970967700 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 719 
8971140130 
INJECTION-PUMP ASSEMBLY
4HF1
 
8971008370 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 720 
8971140140 
INJECTION-PUMP ASSEMBLY
4HF1
101401-4680  

101401-4681 
 
8971006570 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 721 
8971006571 
INJECTION-PUMP ASSEMBLY
4HF1
 
8971067440 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971140480 
INJECTION-PUMP ASSEMBLY
4HE1-T
F 019 Z10 153 
8971197180 
INJECTION-PUMP ASSEMBLY
4HE1-T
9 400 613 722 
8971295680 
INJECTION-PUMP ASSEMBLY
4HE1-T
Back to top