101401-4002 ZEXEL 9 400 613 669 BOSCH INJECTION-PUMP ASSEMBLY 9400613669 1014014002 8970128732


101401-4002 INJECTION-PUMP ASSEMBLY
Rating:
70
Buy INJECTION-PUMP ASSEMBLY 101401-4002 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 613 669 9400613669
ZEXEL 101401-4002 1014014002
ISUZU 8970128732 8970128732

Service parts 101401-4002 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-8800
3. GOVERNOR 105931-6651
4. SUPPLY PUMP 105210-6130
5. AUTOM. ADVANCE MECHANIS 105671-0140
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-4724
11. Nozzle and Holder 8-94479-578-3
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105048-3352
14. NOZZLE 105017-0640
15. NOZZLE SET

Include in #1:

101401-4002 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 613 669 9400613669
ZEXEL 101401-4002 1014014002
ISUZU 8970128732 8970128732


Zexel num
Bosch num
Firm num
Name
101401-4002 
9 400 613 669 
8970128732  ISUZU
INJECTION-PUMP ASSEMBLY
4BG1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.6 3.55 3.65
Rack position
Point A
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.3
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   69.6 68 71.2
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   9.8 8.5 11.1
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.3)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   69.6 68.6 70.6
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.15
Pump speed r/min   1525 1525 1525
Average injection quantity mm3/st.   82.1 78.9 85.3
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1(11.3)
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   53.1 49.9 56.3
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   86 78 94
Fixing the lever   *
Timer adjustment
Pump speed r/min   1370--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1320
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-4002
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=D65
----------

Speed control lever angle

Test data 101401-4002
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=4.5deg+-5deg b=(31.5deg)+-3deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=1000r/min Ra=8.9+-0.1mm
----------

Timing setting

Test data 101401-4002
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(100deg)




Have questions with 101401-4002?





Group cross 101401-4002 ZEXEL

Isuzu 

 
8970128730 
INJECTION-PUMP ASSEMBLY
4BG1
 
8970128731 
INJECTION-PUMP ASSEMBLY
4BG1
101401-4002  
9 400 613 669 
8970128732 
INJECTION-PUMP ASSEMBLY
4BG1
9 400 613 670 
8943102103 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 671 
8970188263 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 672 
8943654353 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 673 
8970186633 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 674 
8970253251 
INJECTION-PUMP ASSEMBLY
4BD1
 
8970279941 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970279951 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970279961 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970279971 
INJECTION-PUMP ASSEMBLY
4HF1
Back to top