101401-1160 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014011160


101401-1160 INJECTION-PUMP ASSEMBLY
Rating:
36
Buy INJECTION-PUMP ASSEMBLY 101401-1160 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-1160 1014011160

Service parts 101401-1160 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-9400
3. GOVERNOR
4. SUPPLY PUMP 105220-5150
5. AUTOM. ADVANCE MECHANIS 105676-0250
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-4120
11. Nozzle and Holder ME017801
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105048-3070
14. NOZZLE 105017-0100
15. NOZZLE SET

Include in #1:

101401-1160 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101401-1160 1014011160


Zexel num
Bosch num
Firm num
Name
101401-1160 
101401-1163 
 
  MITSUBISHI
INJECTION-PUMP ASSEMBLY
4D31T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-6220
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.6
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   55.1 54.1 56.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.7+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   10 8.7 11.3
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.6)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   55.1 54.1 56.1
Basic   *
Fixing the lever   *
Boost pressure kPa   42.7 42.7
Boost pressure mmHg   320 320
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.6
Pump speed r/min   1750 1750 1750
Average injection quantity mm3/st.   73.5 69.5 77.5
Fixing the lever   *
Boost pressure kPa   42.7 42.7
Boost pressure mmHg   320 320
Injection quantity adjustment_05
Adjusting point   C
Rack position   R2(R1-0. 4)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   39.9 35.9 43.9
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_06
Adjusting point   D
Rack position   R2+0.4
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   35.7 31.7 39.7
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   67 67 72
Fixing the lever   *
Rack limit   *
Boost compensator adjustment
Pump speed r/min   700 700 700
Rack position   R1-0.4
Boost pressure kPa   22.7 21.4 24
Boost pressure mmHg   170 160 180
Boost compensator adjustment_02
Pump speed r/min   700 700 700
Rack position   R1(10.6)
Boost pressure kPa   36 29.3 36
Boost pressure mmHg   270 220 270
Timer adjustment
Pump speed r/min   -
Advance angle deg.   0 0 0
Remarks
Measure speed (beginning of operation).
 
Timer adjustment_02
Pump speed r/min   1700
Advance angle deg.   3.5 3 4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-1160
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT (3)Boost compensator stroke: BCL
----------
T1=B71 BCL=0.4+-0.1mm
----------

Speed control lever angle

Test data 101401-1160
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=40mm
----------
a=26deg+-5deg b=42deg+-3deg

Stop lever angle

Test data 101401-1160
N:Engine manufacturer's normal use S:Stop the pump. (1)Free (at shipping) (2)Use the hole at R = aa (3)Rack position corresponding to bb (4)Set the stopper bolt so that speed = cc and rack position = dd. (5)After setting the stopper bolt, confirm non-injection at speed ee. (Rack position = ff or less)
----------
aa=40mm bb=16mm cc=1700r/min dd=6.5-0.5mm ee=325r/min ff=8mm
----------
a=8deg+-5deg b=15deg+-5deg c=25deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=1050+-5r/min Ra=8mm
----------

0000001601 ACTUATOR

Test data 101401-1160
(a) Screw (B) Nut Bolt c (d) Speed lever (e) Actuator shaft 1. Actuator adjustment procedure (1)Position the speed lever (d) in the idle position. (2)Set bolt (c) so that the clearance between the speed lever (d)'s pin and the actuator shaft (e) is approximately L1. (3)Loosen the nut (b) and fully tighten the screw (a). (4)Set the pump speed at N1 and read the rack position when negative pressure P1 is applied to the actuator. (5)Gradually loosen screw (a) and fix the nut (b) when the pump speed is N2 and the rack position is R1. (6)Apply negative pressure several times and confirm that the lever (d) returns to the idle position at negative pressure '0.' (7)Confirm that rack position is R2 when negative pressure is P2.
----------
L1=2mm N1=500r/min P1=66.7kPa(500mmHg) N2=500r/min R1=9.1mm P2=66.7kPa(500mmHg) R2=9.1mm
----------

Timing setting

Test data 101401-1160
(1)Pump vertical direction (2)Position of gear mark '3' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(130deg)




Have questions with 101401-1160?





Group cross 101401-1160 ZEXEL

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 392 
ME016323 
INJECTION-PUMP ASSEMBLY
4D31T

Mitsubishi-Heav 

 
4262400900 
INJECTION-PUMP ASSEMBLY
S4MB

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 056 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 188 
ME016321 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016234 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016310 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 057 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 613 599 
ME016341 
INJECTION-PUMP ASSEMBLY
4D31T
101401-1160  

101401-1163 
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016235 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016236 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 613 600 
ME016327 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 613 601 
ME016450 
INJECTION-PUMP ASSEMBLY
4D31T
Back to top