101401-0040 ZEXEL 9 400 613 544 BOSCH INJECTION-PUMP ASSEMBLY 9400613544 1014010040 5156004742


101401-0040 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 101401-0040 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 613 544 9400613544
ZEXEL 101401-0040 1014010040
ISUZU 5156004742 5156004742

Service parts 101401-0040 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-8000
3. GOVERNOR 105931-0070
4. SUPPLY PUMP 105220-1871
5. AUTOM. ADVANCE MECHANIS 105622-0400
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-4971
11. Nozzle and Holder 5-15300-065-1
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105031-3471
14. NOZZLE 105015-3600
15. NOZZLE SET

Include in #1:

101401-0040 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 613 544 9400613544
ZEXEL 101401-0040 1014010040
ISUZU 5156004742 5156004742


Zexel num
Bosch num
Firm num
Name
101401-0040 
9 400 613 544 
5156004742  ISUZU
INJECTION-PUMP ASSEMBLY
4BB1-2 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.5+-0. 5
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   53 52 54
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.25+-0 .5
Pump speed r/min   1650 1650 1650
Average injection quantity mm3/st.   49.8 48.2 51.4
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   10.45+-0 .5
Pump speed r/min   1350 1350 1350
Average injection quantity mm3/st.   54.8 53.2 56.4
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   D
Rack position   10.35+-0 .5
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   41.8 39.4 42.6
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   E
Rack position   11.15+-0 .5
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   47.8 45.8 49.8
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   F
Rack position   10.7+-0. 5
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   44 42 46
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   -
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   8 6.7 9.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Injection quantity adjustment_08
Adjusting point   I
Rack position   13.2+-0. 5
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   72 72 77
Fixing the rack   *
Remarks
Rack limit setting
 
Timer adjustment
Pump speed r/min   1100+-50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1300
Advance angle deg.   0.8 0.3 1.3
Timer adjustment_03
Pump speed r/min   1500
Advance angle deg.   2 1.5 2.5
Timer adjustment_04
Pump speed r/min   1650
Advance angle deg.   3 2.5 3.5
Timer adjustment_05
Pump speed r/min   -
Advance angle deg.   5 5 5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101401-0040
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT (3)Because the figures in brackets are the target values at torque cam adjustment, perform final adjustment in accordance with governor and injection quantity adjustment standards. (4)Perform governor spring adjustment by setting lever a. (5)After adjustment of the lever a setting, set the lever so that idle set point H can be obtained and confirm standard b. (6)After completing final adjustment, set the lever to obtain J. (7)Next, confirm rack position R1 or more is obtained when rotation is stopped. (8)In this condition, move the lever to the full position and confirm standard c. (excess fuel for starting operation limit). (9)After completing final adjustment, set speed at N1 using lever b. (10)In this condition, after operating the lever to the full position, confirm no excess fuel for starting (black smoke prevention limit). (11)For the excess fuel setting for starting rack position point I set the lever to obtain standard c in step (8) and then set the rack limit.
----------
T1=07 R1=12mm N1=225r/min
----------

Speed control lever angle

Test data 101401-0040
F:Full speed I:Idle (1)Stopper bolt set position 'b.'
----------

----------
a=30deg+-5deg b=41deg+-3deg




Have questions with 101401-0040?





Group cross 101401-0040 ZEXEL

Isuzu 

 
5156005350 

 
5156004740 

 
5156006823 
INJECTION-PUMP ASSEMBLY
4BB1
101401-0040  
9 400 613 544 
5156004742 
INJECTION-PUMP ASSEMBLY
4BB1-2
 
5156005352 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156005872 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156006351 

4BB1
 
5156006361 

4BB1
 
5156006371 

4BB1
Back to top